Literature DB >> 12856771

Bispectral index, spectral edge frequency 95%, and median frequency recorded for various concentrations of isoflurane and sevoflurane in pigs.

María F Martín-Cancho1, Juan R Lima, Laura Luis, Verónica Crisóstomo, Luis J Ezquerra, María S Carrasco, Jesús Usón-Gargallo.   

Abstract

OBJECTIVE: To evaluate bispectral index (BIS), spectral edge frequency 95% (SEF), and median frequency (MED) in relation to a visual analogue scale (VAS) as indicators of anesthetic depth for various concentrations of sevoflurane and isoflurane in pigs. ANIMALS: 32 pigs. PROCEDURE: Pigs were randomly allocated to 8 groups (4 pigs/group). An electroencephalogram (EEG) was recorded in each conscious pig. Pigs were then anesthetized by use of sevoflurane (n = 16) or isoflurane (16). Agents were administered in oxygen at minimum alveolar concentrations (MACs) of 1, 1.25, 1.5, and 1.75 MAC in a randomized order. End-tidal sevoflurane and isoflurane concentrations were maintained for 30 minutes, after which an EEG was recorded for 5 minutes; BIS, SEF, and MED were then calculated. Anesthetic depth was evaluated by use of the VAS. Cardiovascular and EEG responses to nociceptive stimuli were evaluated for each anesthetic agent.
RESULTS: BIS decreased significantly for the various concentrations of each anesthetic. At equivalent MACs, BIS values were significantly higher during sevoflurane-induced anesthesia than during isoflurane-induced anesthesia. Values of MED and SEF decreased significantly from basal values to 1 MAC of sevoflurane and isoflurane. For both agents, there was good correlation between VAS scores and BIS values and between VAS scores and SEF values. CONCLUSIONS AND CLINICAL RELEVANCE: BIS was useful for predicting changes in anesthetic depth at clinical dosages of inhalant anesthetics. Values of BIS, SEF, and MED were significantly higher during anesthesia induced by administration of sevoflurane than during anesthesia induced by administration of isoflurance at equivalent MACs.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12856771     DOI: 10.2460/ajvr.2003.64.866

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  5 in total

1.  Comparison of Heart Rate and Blood Pressure with Toe Pinch and Bispectral Index for Monitoring the Depth of Anesthesia in Piglets.

Authors:  Samer M Jaber; Sarah Sullivan; F Claire Hankenson; Todd J Kilbaugh; Susan S Margulies
Journal:  J Am Assoc Lab Anim Sci       Date:  2015-09       Impact factor: 1.232

2.  Physiologic Responses to Infrarenal Aortic Cross-Clamping during Laparoscopic or Conventional Vascular Surgery in Experimental Animal Model: Comparative Study.

Authors:  María F Martín-Cancho; Verónica Crisóstomo; Federico Soria; Carmen Calles; Francisco M Sánchez-Margallo; Idoia Díaz-Güemes; Jesús Usón-Gargallo
Journal:  Anesthesiol Res Pract       Date:  2008-03-27

3.  Clinical Use of a Multivariate Electroencephalogram (Narcotrend) for Assessment of Anesthetic Depth in Horses during Isoflurane-Xylazine Anesthesia.

Authors:  Julia Tünsmeyer; Klaus Hopster; Sabine B Kästner
Journal:  Front Vet Sci       Date:  2016-03-17

4.  Correlation of Sedline-generated variables and clinical signs with anaesthetic depth in experimental pigs receiving propofol.

Authors:  Alessandro Mirra; Claudia Spadavecchia; Olivier Levionnois
Journal:  PLoS One       Date:  2022-09-29       Impact factor: 3.752

5.  Effects of acute bleeding followed by hydroxyethyl starch 130/0.4 or a crystalloid on propofol concentrations, cerebral oxygenation, and electroencephalographic and haemodynamic variables in pigs.

Authors:  Aura Silva; Ana Liza Ortiz; Carlos Venâncio; Almir P Souza; Luísa Maria Ferreira; Paula Sério Branco; Paula Guedes de Pinho; Pedro Amorim; David A Ferreira
Journal:  Vet Med Int       Date:  2014-05-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.