Use of BANG polymer gel for dose measurements in a 68 MeV proton beam.

J Heufelder1, S Stiefel, M Pfaender, L Lüdemann, G Grebe, J Heese.   

Abstract

BANG polymer gel dosimetry using magnetic resonance imaging (MRI) was applied to an ophthalmologic 68 MeV proton beam. The object was to examine the use of BANG gel for the verification of proton fields in eye tumor therapy and to explore the applicability of polymer gel dosimetry in proton therapy under practical aspects. The gel phantoms were irradiated with monoenergetic and modulated proton beams. MRI analysis was carried out at clinical 1.5 and 3 T MR scanners. At constant LET, results show a linear relationship between spin-spin relaxation rates and dose. However, depth dose curves in BANG gel reveal a quenching of the Bragg maximum due to LET effects. The dose response of the gel for monoenergetic protons and spread-out depth dose distributions can be calculated based on ionization chamber measurements. Experiment and calculations show good agreement and indicate that BANG polymer gels might become a valuable tool in proton therapy quality assurance.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12852548     DOI: 10.1118/1.1575557

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Determination of the depth dose distribution of proton beam using PRESAGE™ dosimeter.

Authors:  L Zhao; I J Das; Q Zhao; A Thomas; J Adamovics; M Oldman
Journal:  J Phys Conf Ser       Date:  2010

2.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

3.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

4.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

Review 5.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

6.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

Review 7.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

8.  MAGIC polymer gel for dosimetric verification in boron neutron capture therapy.

Authors:  Jouni Uusi-Simola; Sami Heikkinen; Petri Kotiluoto; Tom Serén; Tiina Seppälä; Iiro Auterinen; Sauli Savolainen
Journal:  J Appl Clin Med Phys       Date:  2007-04-30       Impact factor: 2.102