Literature DB >> 12850416

Analysis of ecstasy tablets: comparison of reflectance and transmittance near infrared spectroscopy.

Ralph Carsten Schneider1, Karl-Artur Kovar.   

Abstract

Calibration models for the quantitation of commonly used ecstasy substances have been developed using near infrared spectroscopy (NIR) in diffuse reflectance and in transmission mode by applying seized ecstasy tablets for model building and validation. The samples contained amphetamine, N-methyl-3,4-methylenedioxy-amphetamine (MDMA) and N-ethyl-3,4-methylenedioxy-amphetamine (MDE) in different concentrations. All tablets were analyzed using high performance liquid chromatography (HPLC) with diode array detection as reference method. We evaluated the performance of each NIR measurement method with regard to its ability to predict the content of each tablet with a low root mean square error of prediction (RMSEP). Best calibration models could be generated by using NIR measurement in transmittance mode with wavelength selection and 1/x-transformation of the raw data. The models build in reflectance mode showed higher RMSEPs using as data pretreatment, wavelength selection, 1/x-transformation and a second order Savitzky-Golay derivative with five point smoothing was applied to obtain the best models. To estimate the influence of inhomogeneities in the illegal tablets, a calibration of the destroyed, i.e. triturated samples was build and compared to the corresponding data of the whole tablets. The calibrations using these homogenized tablets showed lower RMSEPs. We can conclude that NIR analysis of ecstasy tablets in transmission mode is more suitable than measurement in diffuse reflectance to obtain quantification models for their active ingredients with regard to low errors of prediction. Inhomogeneities in the samples are equalized when measuring the tablets as powdered samples.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12850416     DOI: 10.1016/s0379-0738(03)00125-7

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  3 in total

1.  Enhanced phase regression with Savitzky-Golay filtering for high-resolution BOLD fMRI.

Authors:  Robert L Barry; John C Gore
Journal:  Hum Brain Mapp       Date:  2014-01-17       Impact factor: 5.038

2.  A nonlinear generalization of the Savitzky-Golay filter and the quantitative analysis of saccades.

Authors:  Weiwei Dai; Ivan Selesnick; John-Ross Rizzo; Janet Rucker; Todd Hudson
Journal:  J Vis       Date:  2017-08-01       Impact factor: 2.240

3.  Forensic Analysis of Textile Synthetic Fibers Using a FT-IR Spectroscopy Approach.

Authors:  Abdulrahman Aljannahi; Roudha Abdulla Alblooshi; Rashed Humaid Alremeithi; Ioannis Karamitsos; Noora Abdulkarim Ahli; Asma Mohammed Askar; Ikhlass Mohammed Albastaki; Mohamed Mahmood Ahli; Sanjay Modak
Journal:  Molecules       Date:  2022-07-03       Impact factor: 4.927

  3 in total