Literature DB >> 12848874

Automated quantification of left ventricular function by the automated contour tracking method.

Kenichi Sugioka1, Takeshi Hozumi, Toshikazu Yagi, Atsushi Yamamuro, Takashi Akasaka, Kazuhide Takeuchi, Shunichi Homma, Kiyoshi Yoshida, Junichi Yoshikawa.   

Abstract

The automated contour tracking (ACT) method has been developed for the automated measurement of area volume using the energy minimization method without tracing a region of interest. The purpose of this study was to compare the ACT method and left ventriculography (LVG) for the measurement of left ventricular (LV) function in the clinical setting. An apical four-chamber view was visualized by two-dimensional echocardiography and recorded for off-line analysis in 14 patients with high-quality images who underwent LVG. The ACT method automatically traces the endocardial border from the recorded images and calculates LV volumes (end-diastole and end-systole) and ejection fraction (EF). Both ACT and LVG were compared by linear regression analysis for the measurement of EF. EF determined by the ACT method agreed well with that by LVG (r = 0.96, y = 0.94x + 4.6, standard error of the estimate = 3.9%). The mean difference between the ACT and LVG was -1.4%+/- 7.3%. In conclusion, the ACT method is reliable for noninvasive estimation of EF in high-quality images. This suggests that this new technique may be useful in the automated quantification of LV function.

Entities:  

Mesh:

Year:  2003        PMID: 12848874     DOI: 10.1046/j.1540-8175.2003.03036.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Assessment of left ventricular volume and function by integration of simplified 3D echocardiography, tissue harmonic imaging and automated extraction of endocardial borders.

Authors:  Donato Mele; Roberta Teoli; Corrado Cittanti; Giovanni Pasanisi; Gabriele Guardigli; Robert A Levine; Roberto Ferrari
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

2.  Troponin T for the detection of dialysis-induced myocardial stunning in hemodialysis patients.

Authors:  Tobias Breidthardt; James O Burton; Aghogho Odudu; Mohamed Tarek Eldehni; Helen J Jefferies; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2012-07-19       Impact factor: 8.237

3.  Semi-automated echocardiographic quantification of right ventricular size and function.

Authors:  Diego Medvedofsky; Karima Addetia; Jamie Hamilton; Javier Leon Jimenez; Roberto M Lang; Victor Mor-Avi
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-07       Impact factor: 2.357

4.  Hemodialysis-induced cardiac injury: determinants and associated outcomes.

Authors:  James O Burton; Helen J Jefferies; Nicholas M Selby; Christopher W McIntyre
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-08       Impact factor: 8.237

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.