Literature DB >> 12845595

Optimization of matrix-assisted laser desorption/ionization time-of-flight collision-induced dissociation using poly(ethylene glycol).

Andrew J Hoteling1, Kenji Kawaoka, Mary C Goodberlet, Wan-Mo Yu, Kevin G Owens.   

Abstract

Details of the optimization of the collision-induced dissociation (CID) process, using a collision cell on a matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometer, are described using poly(ethylene glycol) 1000 (PEG 1000) as a model analyte. The effects of collision gas identity (helium, air, and argon), as well as collision gas pressure, on the resulting MS/MS data were investigated. With PEG 1000, helium was found to give the best results with respect to signal-to-noise (S/N) ratio. The optimum pressure for each gas was found to be in the range where the precursor ion signal was attenuated to approximately 30-50% for helium and 40-60% for argon. The effect of cation choice (Li, Na, and K) on the CID of PEG was also studied. CID spectra were produced for each, but PEG cationized with lithium was found to produce the spectra with the highest S/N ratio. The MALDI-TOF CID spectra that were generated for PEG were compared with the high-energy and low-energy MS/MS spectra obtained from a sector mass spectrometer and from a triple quadrupole mass spectrometer, respectively. The results observed for PEG confirm that CID on a MALDI-TOF mass spectrometer is a high-energy MS/MS technique. Copyright 2003 John Wiley & Sons, Ltd.

Entities:  

Year:  2003        PMID: 12845595     DOI: 10.1002/rcm.1084

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  Tandem mass spectrometry of trimethylsilyl-terminated poly(dimethylsiloxane) ammonium adducts generated by electrospray ionization.

Authors:  Thierry Fouquet; Stéphane Humbel; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2011-02-15       Impact factor: 3.109

2.  Tandem mass spectrometry of poly(methacrylic Acid) oligomers produced by negative mode electrospray ionization.

Authors:  Rémi Giordanengo; Stéphane Viel; Béatrice Allard-Breton; André Thévand; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2008-09-25       Impact factor: 3.109

3.  Microstructural study of a nitroxide-mediated poly(ethylene oxide)/polystyrene block copolymer (PEO-b-PS) by electrospray tandem mass spectrometry.

Authors:  Marion Girod; Trang N T Phan; Laurence Charles
Journal:  J Am Soc Mass Spectrom       Date:  2008-04-30       Impact factor: 3.109

4.  Solid-state NMR spectroscopy as a tool supporting optimization of MALDI-TOF MS analysis of polylactides.

Authors:  Anna Sroka-Bartnicka; Sebastian Olejniczak; Marek Sochacki; Tadeusz Biela; Marek J Potrzebowski
Journal:  J Am Soc Mass Spectrom       Date:  2008-09-23       Impact factor: 3.109

5.  Improved PSD and CID on a MALDI TOFMS.

Authors:  Andrew J Hoteling; Kevin G Owens
Journal:  J Am Soc Mass Spectrom       Date:  2004-04       Impact factor: 3.109

  5 in total