Literature DB >> 12844204

Continuous measurement of metals in flue gas using ICP-OES.

P J Clarkson1, D J Poole, C K Ryu, V N Sharifi, J Swithenbank, H-J Waarlo, D Ardelt, H Falk.   

Abstract

A system capable of continuously measuring a range of metallic elements in the effluent gas from incinerators and other similar industrial processes, and providing on-line results has been developed. With a state-of-the-art mobile laboratory measurements were taken from a UK municipal solid waste incinerator. The detection system used was an ICP-OES, with a modified torch to allow the introduction of flue gas directly into the plasma. Metals that were investigated were Ni, Hg, V, Al, Na, Ca, Cu, Sn, Pb, Sb, As, Cd and Tl, with limits of detection in the range 0.0004 mg m(-3) to 0.1 mg m(-3) being calculated. Emission measurements produced data that showed that the MSWI plants emission were significantly lower than the emission limits specified in EC 2000/76/EC.

Entities:  

Year:  2003        PMID: 12844204     DOI: 10.1007/s00216-003-2030-y

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  1 in total

1.  Entrained Metal Aerosol Emissions from Air-Fired Biomass and Coal Combustion for Carbon Capture Applications.

Authors:  Karen N Finney; János Szuhánszki; Leilani I Darvell; Benjamin Dooley; Kris Milkowski; Jenny M Jones; Mohamed Pourkashanian
Journal:  Materials (Basel)       Date:  2018-09-25       Impact factor: 3.623

  1 in total