Literature DB >> 12843722

Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure?

Damian R Griffin1, Adam J Starr, Charles M Reinert, Alan L Jones, Shelly Whitlock.   

Abstract

OBJECTIVE: To measure the failure rate of percutaneous iliosacral screw fixation of vertically unstable pelvic fractures and particularly to test the hypothesis that fixations in which the posterior injury is a vertical fracture of the sacrum are more likely to fail than fixations with dislocations or fracture-dislocations of the sacroiliac joint.
DESIGN: Retrospective review.
SETTING: Level 1 trauma center.
METHODS: All patients with pelvic fractures admitted between January 1, 1993, and December 31, 1998, were identified from the trauma registry. Hospital records were used to identify patients treated with iliosacral screws. Radiologic studies were examined to identify patients who had unequivocally vertically unstable pelvic fractures. Immediate postoperative and follow-up anteroposterior, inlet, and outlet radiographs from a minimum of 12 months postinjury were examined. Position, length, and numbers of iliosacral screws and any evidence of screw failure (eg, bending or breakage) were recorded. Residual postoperative displacement and late displacement of the posterior pelvis were measured. The main outcome measure was failure, defined as at least 1cm of combined vertical displacement of the posterior pelvis compared with immediate postoperative position. The main analysis was for association between fracture pattern and failure. Patient demographic data, iliosacral screw position, and anterior pelvic fixation method also were studied.
RESULTS: The study group comprised 62 patients with unequivocally vertically unstable pelvic fractures in whom the posterior injury was treated with closed reduction and percutaneous iliosacral screw fixation. Of patients, 32 had dislocations or fracture-dislocations of the sacroiliac joint, and 30 had vertical fractures of the sacrum. Fixation failed in four patients, all with vertical sacral fractures and all within the first 3 weeks after surgery. These four patients required revision fixation. In two further cases with vertical sacral fractures, there was evidence that the fracture had only barely been held by the fixation, but these fractures healed, and follow-up radiographs did not meet the displacement criteria for failure. A vertical sacral fracture pattern was associated significantly with failure (Fisher exact test, P = 0.04); the excess risk of failure compared with sacroiliac joint injury was 13% (95% confidence interval 1% to 25%). There was no significant association between failure and anterior fixation method, iliosacral screw arrangement or length, or any demographic or injury variable.
CONCLUSIONS: Percutaneous iliosacral screw fixation is a useful technique in the management of vertically unstable pelvic fractures, but a vertical sacral fracture should make the surgeon more wary of fixation failure and loss of reduction.

Entities:  

Mesh:

Year:  2003        PMID: 12843722     DOI: 10.1097/00005131-200307000-00001

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  36 in total

1.  What is the infection rate of the posterior approach to type C pelvic injuries?

Authors:  Michael D Stover; Stephen Sims; Joel Matta
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

2.  Persistent impairment after surgically treated lateral compression pelvic injury.

Authors:  Martin F Hoffmann; Clifford B Jones; Debra L Sietsema
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

3.  Can lumbopelvic fixation salvage unstable complex sacral fractures?

Authors:  Clifford B Jones; Debra L Sietsema; Martin F Hoffmann
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

4.  Standalone percutaneous transiliac plating of vertically unstable sacral fractures: outcomes, complications, and recommendations.

Authors:  Mostafa A Ayoub; Hossam M Gad; Osama A Seleem
Journal:  Eur Spine J       Date:  2015-04-22       Impact factor: 3.134

5.  Biomechanical comparison of three types of internal fixation in a type C zone II pelvic fracture model.

Authors:  Tao Wu; Wei Chen; Xu Li; Qi Zhang; Hong-Zhi Lv; Ying-Ze Zhang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

6.  Nonunion of a sacral fracture refractory to bone grafting: internal fixation and osteogenic protein-1 (BMP-7) application.

Authors:  Alberto Nicodemo; Marcello Capella; Martino Deregibus; Alessandro Massè
Journal:  Musculoskelet Surg       Date:  2011-05-26

7.  Fully threaded sacroiliac lag screws have higher load to failure when compared to partially threaded screws: A biomechanical study.

Authors:  Huai Ming Phen; Brent Wise; Daniel Thompson; Jason Nascone; Adam Boissonneault; Michael Maceroli
Journal:  J Clin Orthop Trauma       Date:  2020-10-19

8.  Transcondylar traction as a closed reduction technique in vertically unstable pelvic ring disruption.

Authors:  M Thaunat; F Laude; P Paillard; G Saillant; Y Catonné
Journal:  Int Orthop       Date:  2007-01-24       Impact factor: 3.075

9.  [Unilateral triangular lumbopelvic stabilization: indications and techniques].

Authors:  M F Hoffmann; M Dudda; T A Schildhauer
Journal:  Unfallchirurg       Date:  2013-11       Impact factor: 1.000

10.  Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

Authors:  Colin G Murphy; James R Gill; Andrew D Carrothers; Peter D Hull
Journal:  Arch Bone Jt Surg       Date:  2016-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.