Literature DB >> 12843623

Noninvasive glucose monitoring by back diffusion via skin: chemical and physical enhancements.

Yaw-Bin Huang1, Jia-You Fang, Pao-Chu Wu, Tsung-Hsien Chen, Ming-Jun Tsai, Yi-Hung Tsai.   

Abstract

Blood glucose levels are routinely obtained by invasive and painful methods using glucose meters and test strips. The development of less invasive or non invasive techniques would be beneficial for diabetes patients. In this study, a noninvasive method was evaluated using the back diffusion of glucose across skin with or without permeation enhancement methods. An in vitro model was utilized. The stratum corneum (SC) was the predominant barrier for both back and forward diffusion of glucose across skin. Surfactants with various charges and essential oils (cyclic monoterpenes) were used as chemical enhancers to promote the back diffusion of glucose. A cationic surfactant (benzalkonium chloride) showed the highest enhancement, followed by anionic and nonionic surfactants. d-Limonene and 1,8-cineole dispersed in appropriate proportions of ethanol could enhance the glucose diffusion after pretreatment of the skin surface. Electroporation, defined as a physical method, significantly increased the amount of glucose that diffused back. The percentages of diffused glucose by 300 V (volts) and 500 V high voltage pulses on skin for 10 min were found to be 45 and 75 times greater than the control group, respectively.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12843623     DOI: 10.1248/bpb.26.983

Source DB:  PubMed          Journal:  Biol Pharm Bull        ISSN: 0918-6158            Impact factor:   2.233


  4 in total

1.  Detection of trace glucose on the surface of a semipermeable membrane using a fluorescently labeled glucose-binding protein: a promising approach to noninvasive glucose monitoring.

Authors:  Xudong Ge; Govind Rao; Yordan Kostov; Sunsanee Kanjananimmanont; Rose M Viscardi; Hyung Woo; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

2.  Passive Diffusion of Transdermal Glucose: Noninvasive Glucose Sensing Using a Fluorescent Glucose Binding Protein.

Authors:  Sunsanee Kanjananimmanont; Xudong Ge; KarunaSri Mupparapu; Govind Rao; Russell Potts; Leah Tolosa
Journal:  J Diabetes Sci Technol       Date:  2014-01-21

3.  Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics.

Authors:  Jonas Kottmann; Julien M Rey; Markus W Sigrist
Journal:  Sensors (Basel)       Date:  2016-10-10       Impact factor: 3.576

4.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection.

Authors:  Jonas Kottmann; Julien M Rey; Joachim Luginbühl; Ernst Reichmann; Markus W Sigrist
Journal:  Biomed Opt Express       Date:  2012-03-01       Impact factor: 3.732

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.