Literature DB >> 12841695

Amniotic fluid index in normal pregnancy: an assessment of gestation specific reference values among Indian women.

Suvarna S Khadilkar1, Sabita S Desai, Sadhana M Tayade, Chittaranjan N Purandare.   

Abstract

AIM: To obtain a gestational reference range for the amniotic fluid index (AFI) among Indian women.
METHODS: An analysis of AFI estimations was undertaken in 517 Indian women with normal pregnancy between 16 and 42 weeks of gestation. It was a prospective, cross-sectional study conducted in a university teaching hospital. Women with fetal anomalies, pregnancy-induced hypertension, diabetes mellitus, and other maternal complications were excluded from the study. The median, the 5th and the 95th percentile values were calculated for each gestational week and these values were compared with other studies.
RESULTS: The median reached its peak at the 27th week of gestation. We observed approximately 6 cm as the lower limit of normal (5th percentile) and approximately 18 cm (95th percentile) as upper limit of normal AFI at term for our population, whereas in the Caucasian population, the values were approximately 7 cm and approximately 20 cm, respectively. All gestation specific AFI values were lower in the studied population of Indian women compared with other studies on Caucasian population (P < 0.01 for 5th percentile &amp; P < 3.26 x 10(-7) for 95th percentile), but slightly higher than the Chinese population.
CONCLUSION: Amniotic fluid index values differ in different populations. We standardized the reference values for normal AFI in Indian women. We found that they are lower in the population studied compared with reported values in the Caucasian population, but slightly higher than the Chinese population.

Entities:  

Mesh:

Year:  2003        PMID: 12841695     DOI: 10.1046/j.1341-8076.2003.00089.x

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  2 in total

1.  Reference ranges of amniotic fluid index in late third trimester of pregnancy: what should the optimal interval between two ultrasound examinations be?

Authors:  Shripad Hebbar; Lavanya Rai; Prashant Adiga; Shyamala Guruvare
Journal:  J Pregnancy       Date:  2015-01-15

2.  Relationship of amniotic fluid index (AFI) in third trimester with fetal weight and gender in a southeast Nigerian population.

Authors:  Emeka John Agwu; Anthony C Ugwu; Samuel L Shem; Muhammed Abba
Journal:  Acta Radiol Open       Date:  2016-08-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.