Literature DB >> 12838473

[Vertebral body replacement system Synex in unstable burst fractures of the thoracic and lumbar spine--a retrospective study with 30 patients].

U Vieweg1, O Sölch, R Kalff.   

Abstract

OBJECTIVES: Retrospective analysis of the vertebral body replacement system Synex in unstable burst fractures of the lumbar and thoracic spine. PATIENTS AND METHODS: Within 22 months, we treated 30 patients (average age: 45, range: 20- 73 years, 16 females, 14 males) with unstable burst fractures of the thoracolumbar (n=20) and the thoracic (n=2) as well as lumbar (n=8) spine in two stages (primary dorsal transpedicular stabilization with fixateur interne under navigator guidance and intraoperative CT and secondary vertebral body replacement using the Synex). In three patients with osteoporosis we performed additional ventrolateral plate fixation. The complications of the operation were analyzed and the postoperative follow-up results were evaluated regarding stability, bony fusion, loss of correction, pain and neurological status.
RESULTS: There was one postoperative instability, two transient neurological deteriorations and one case with seroma of the pleura. At follow-up examination (mean follow-up 14 months) an average loss of correction of 1.6 degrees was measured. Without osteoporosis a loss of correction of 5 degrees was observed in one case. In four osteoporotic patients without ventrolateral stabilization a mean loss of correction of 10 degrees was present. At the follow-up examinations a bony fusion was documented in 27 and stability in all patients. Most of the patients stated either no or only minor pains at follow-up. Only two patients with pain of medium degree had to take pain medication.
CONCLUSIONS: The vertebral body replacement system Synex is a good technical possibility for a vertebral body replacement in unstable burst fractures of the thoracic and lumbar spine. With osteoporosis an additional anterior stabilization is to be recommended.

Entities:  

Mesh:

Year:  2003        PMID: 12838473     DOI: 10.1055/s-2003-40373

Source DB:  PubMed          Journal:  Zentralbl Neurochir        ISSN: 0044-4251


  7 in total

1.  Mid-term results of PLIF/TLIF in trauma.

Authors:  Rene Schmid; Dietmar Krappinger; Michael Blauth; Anton Kathrein
Journal:  Eur Spine J       Date:  2010-10-31       Impact factor: 3.134

2.  [Sintering prophylaxis of a vertebral body replacement: anterior cement augmentation of vertebral end plates].

Authors:  F Geiger; K Kafchitsas; M Rauschmann
Journal:  Orthopade       Date:  2010-07       Impact factor: 1.087

3.  [Titanium vertebral body replacement of adjustable size. A prospective clinical trial].

Authors:  U Lange; S Edeling; C Knop; L Bastian; C Krettek; M Blauth
Journal:  Unfallchirurg       Date:  2006-09       Impact factor: 1.000

4.  Anterior vertebroplasty of adjacent levels after vertebral body replacement.

Authors:  Florian Geiger; Konstantinos Kafchitsas; Michael Rauschmann
Journal:  Eur Spine J       Date:  2011-03-30       Impact factor: 3.134

5.  Anterior vertebral body replacement with a titanium implant of adjustable height: a prospective clinical study.

Authors:  Uta Lange; Sebastian Edeling; Christian Knop; Leonard Bastian; Michael Oeser; Christian Krettek; Michael Blauth
Journal:  Eur Spine J       Date:  2006-05-13       Impact factor: 3.134

6.  Combined posterior-anterior stabilisation of thoracolumbar injuries utilising a vertebral body replacing implant.

Authors:  Christian Knop; T Kranabetter; M Reinhold; M Blauth
Journal:  Eur Spine J       Date:  2009-04-09       Impact factor: 3.134

7.  [Fusion criteria for cages as vertebral body replacement in thoracolumbar fractures].

Authors:  K J Schnake; T Görler; F Kandziora
Journal:  Unfallchirurg       Date:  2014-11       Impact factor: 1.000

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.