Polymerization of resin composite restorative materials: exposure reciprocity.

L Musanje1, B W Darvell.   

Abstract

OBJECTIVE: To examine whether there is reciprocity between irradiation time and irradiance with regard to the mechanical properties of filled, resin composite restorative materials (RCs).
METHODS: Four visible light-cured RCs, all of shade A3, were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein), Filtek Z250 (FZ) (3M, St Paul, MN, USA) and Prodigy condensable (PR) (Kerr, Orange, CA, USA). Bar specimens (1.0 x 1.5 x 16.0 mm(3)) were cured at irradiances (I) ranging from 25-1500 mW/cm(2) and irradiation times (t) of 1-3000 s. Six specimens at 250 combinations of t and I were prepared and stored in artificial saliva of pH 6, at 37 degrees C for 7d before performing three-point bend tests for flexural strength (F), flexural modulus (E) and total energy to failure (W). Contour plots of property value vs. t and I on log scales were prepared.
RESULTS: The contour plots showed three regions: unset at low I.t, a plateau corresponding to more or less full property development, and connecting ramp. The boundary between the plateau and the ramp suggests the minimum acceptable exposure. No practical lower limit to irradiance was detected, but there may be no benefit from increasing I beyond about 1,000 mW/cm(2). The slopes of the contours in the log-log plots provided a test of the hypothesis of reciprocity. These slopes were approximately -1.5 for HR, TC and PR; and approximately -1 for FZ, compared with the expected value of -1. The general hypothesis therefore fails. The existence of localized maxima in property values is further evidence of that failure, even for FZ. SIGNIFICANCE: Dentists may use any lamp, including LED sources, and attain satisfactory results providing irradiation time is long enough. Manufacturers ought to supply a graph indicating the minimum acceptable exposure for each product for specified curing lamps. Calculations based on total energy delivered to guide irradiation protocols are invalid and do not recognize product behavior.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12837402     DOI: 10.1016/s0109-5641(02)00101-x

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  21 in total

1.  Modulated photoactivation of composite restoration: measurement of cuspal movement using holographic interferometry.

Authors:  Larisa Blažić; Dejan Pantelić; Svetlana Savić-Šević; Branka Murić; Ilija Belić; Bratimir Panić
Journal:  Lasers Med Sci       Date:  2010-03-23       Impact factor: 3.161

2.  Characterization of heat emission of light-curing units.

Authors:  Mohammed A Wahbi; F A Aalam; F I Fatiny; S A Radwan; I Y Eshan; K H Al-Samadani
Journal:  Saudi Dent J       Date:  2012-03-09

3.  Effect of different curing protocols on the mechanical properties of low-viscosity bulk-fill composites.

Authors:  Nicoleta Ilie; Katharina Stark
Journal:  Clin Oral Investig       Date:  2014-05-25       Impact factor: 3.573

4.  Effect of three types of light-curing units on 5-year colour changes of light-cured composite.

Authors:  Onjen Tak; Subutay Han Altintas; Nilgun Ozturk; Aslihan Usumez
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

5.  Curing efficiency of modern LED units.

Authors:  Adam Rencz; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2011-01-14       Impact factor: 3.573

6.  Guidelines for the selection, use, and maintenance of LED light-curing units - Part 1.

Authors:  A C Shortall; R B Price; L MacKenzie; F J T Burke
Journal:  Br Dent J       Date:  2016-10-21       Impact factor: 1.626

7.  Light curing through glass ceramics with a second- and a third-generation LED curing unit: effect of curing mode on the degree of conversion of dual-curing resin cements.

Authors:  Simon Flury; Adrian Lussi; Reinhard Hickel; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2013-02-08       Impact factor: 3.573

8.  The reciprocity law concerning light dose relationships applied to BisGMA/TEGDMA photopolymers: theoretical analysis and experimental characterization.

Authors:  James W Wydra; Neil B Cramer; Jeffrey W Stansbury; Christopher N Bowman
Journal:  Dent Mater       Date:  2014-03-25       Impact factor: 5.304

9.  Effect of Energy Density on the Physical Properties of Resin-Based Restorative Materials when Polymerized with Quartz-Tungsten Halogen or LED-Light.

Authors:  Stefan Ruttermann; Senay Tomruk; Wolfgang H M Raab; Ralf Janda
Journal:  Eur J Dent       Date:  2010-04

10.  Assessment of resin perfusion in hepatic failure in vitro and in vivo.

Authors:  Ying-Jie Wang; Ze-Wen Wang; Bing-Wei Luo; Hong-Ling Liu; Hong-Wei Wen
Journal:  World J Gastroenterol       Date:  2004-03-15       Impact factor: 5.742

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.