Literature DB >> 12837394

The effect of fiber orientation on the thermal expansion coefficients of fiber-reinforced composites.

Arzu Tezvergil1, Lippo V J Lassila, Pekka K Vallittu.   

Abstract

OBJECTIVES: The aim of this study was to characterize the thermal expansion and dimensional changes of fiber-reinforced composite (FRC) according to the fiber orientation, brand of FRC product and polymerization conditions.
METHODS: Cubic specimens (n=5) were prepared from different brands of FRC and particulate filler composites and dimethacrylate monomer resin. The specimens were polymerized with a light-curing device for 40 s or additionally with prolonged polymerization in the light-curing oven for 15 min. Linear coefficients of thermal expansion (LCTE) values for different materials and for FRC with different fiber orientations were determined using a thermomechanical analyzer.
RESULTS: All specimens exhibited linear increase in the value of LCTE between 37 and 67 degrees C. The analysis of ANOVA revealed that orientation of fiber and brand of material had significant effect (P<0.001) on LCTE values for 37-67 degrees C interval. Some interaction between factors also existed. Also, temperature interval 110-150 degrees C had significant effect on the LCTE values according to the curing unit, brand and orientation of fibers. SIGNIFICANCE: The results of this study suggest that the anisotropic nature of FRC exists also with regard to thermal expansion. The variation of LCTE of FRC compared to that of particulate filler composites might influence the interfacial adhesion of FRC appliances.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12837394     DOI: 10.1016/s0109-5641(02)00092-1

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  12 in total

1.  The effect of span length of flexural testing on properties of short fiber reinforced composite.

Authors:  Sufyan Garoushi; Lippo V J Lassila; Pekka K Vallittu
Journal:  J Mater Sci Mater Med       Date:  2011-11-10       Impact factor: 3.896

2.  In vitro assessment of the soft tissue/implant interface using porcine gingival explants.

Authors:  Aous A Abdulmajeed; Jaana Willberg; Stina Syrjänen; Pekka K Vallittu; Timo O Närhi
Journal:  J Mater Sci Mater Med       Date:  2015-01-15       Impact factor: 3.896

Review 3.  Characterisation of Selected Materials in Medical Applications.

Authors:  Kacper Kroczek; Paweł Turek; Damian Mazur; Jacek Szczygielski; Damian Filip; Robert Brodowski; Krzysztof Balawender; Łukasz Przeszłowski; Bogumił Lewandowski; Stanisław Orkisz; Artur Mazur; Grzegorz Budzik; Józef Cebulski; Mariusz Oleksy
Journal:  Polymers (Basel)       Date:  2022-04-09       Impact factor: 4.967

4.  Dimensional stability of short fibre reinforced flowable dental composites.

Authors:  Raju Raju; Ginu Rajan; Paul Farrar; B Gangadhara Prusty
Journal:  Sci Rep       Date:  2021-02-25       Impact factor: 4.379

5.  The effect of exposed glass fibers and particles of bioactive glass on the surface wettability of composite implants.

Authors:  Aous A Abdulmajeed; Lippo V Lassila; Pekka K Vallittu; Timo O Närhi
Journal:  Int J Biomater       Date:  2011-12-27

6.  Effects of Fiber-reinforced Composite Bases on Microleakage of Composite Restorations in Proximal Locations.

Authors:  Tezvergil-Mutluay A; Vallittu P K
Journal:  Open Dent J       Date:  2014-11-28

7.  An Optical System to Monitor the Displacement Field of Glass-fibre Posts Subjected to Thermal Loading.

Authors:  Massimo Corsalini; Francesco Pettini; Daniela Di Venere; Andrea Ballini; Giuseppe Chiatante; Luciano Lamberti; Carmine Pappalettere; Michele Fiorentino; Antonio E Uva; Giuseppe Monno; Antonio Boccaccio
Journal:  Open Dent J       Date:  2016-11-16

8.  Fixed partial dentures in an up to 8-year follow-up.

Authors:  Maximiliano Sérgio Cenci; Paulo Antônio da Rosa Rodolpho; Tatiana Pereira-Cenci; Altair Antoninha Del Bel Cury; Flávio Fernando Demarco
Journal:  J Appl Oral Sci       Date:  2010 Jul-Aug       Impact factor: 2.698

9.  Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials.

Authors:  Koray Soygun; Giray Bolayir; Ali Boztug
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

10.  Effect of cementation technique of individually formed fiber-reinforced composite post on bond strength and microleakage.

Authors:  Dominika Makarewicz; Anna-Maria B Le Bell-Rönnlöf; Lippo V J Lassila; Pekka K Vallittu
Journal:  Open Dent J       Date:  2013-07-26
View more