Literature DB >> 12835212

Proarrhythmic effect of pacemaker stimulation in patients with implanted cardioverter-defibrillators.

Ewald Himmrich1, Oliver Przibille, Christian Zellerhoff, Andreas Liebrich, Stefan Rosocha, Klaus Andreas, Dirk Nebeling, Babatunde Omogbehin, Jürgen Meyer.   

Abstract

BACKGROUND: We sought to determine the potential of right ventricular VVI backup pacing to induce ventricular tachyarrhythmias in patients with implanted cardioverter-defibrillators. METHODS AND
RESULTS: All consecutive patients presenting exclusively with pacemaker-induced tachycardias (PITs) were included in a prospective study using a crossover protocol. Patients were randomized to either group 1 (augmentation of the baseline frequency of the pacemaker to 60 bpm) or group 2 (pacemaker turned off) and were followed up for 1 year and then crossed over to the other programming, looking for reoccurrence of PIT. Of 150 consecutive patients, 39 (26%) had PIT, 13 of them exclusively (8.6%). Forty of 1063 analyzed tachyarrhythmias of all the patients were PIT (3%). Before inclusion in the study, the patients had 2.7+/-0.9 PITs in 11+/-6.5 months with their pacemakers programmed empirically at 42.3 bpm. During the study phase, no PIT occurred while the pacemaker was turned off, whereas programming to 60 bpm led to the recurrence of PIT in 5 of 6 patients (1.4+/-0.6 per patient). At the end of the study, 9 patients underwent a prolonged follow-up with their pacemakers turned off, resulting in spontaneous episodes of ventricular tachycardia/fibrillation in 5 patients, but PITs were no longer observed.
CONCLUSIONS: This crossover protocol proves the potential proarrhythmic effect of pacemaker stimulation in implantable cardioverter-defibrillator patients. Resulting PITs led to clinical symptoms and antitachycardia therapy by the implantable cardioverter-defibrillator. Thus, in patients presenting with PIT but without a pacemaker indication, the pacemaker feature should be turned off, or, alternatively, the longest possible escape interval should be programmed.

Entities:  

Mesh:

Year:  2003        PMID: 12835212     DOI: 10.1161/01.CIR.0000080291.65638.CC

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  13 in total

1.  Incessant ventricular tachycardia, refractory to catheter ablation, in an ICD patient terminated by ICD lead extraction: a case report.

Authors:  Corinna Lenz; Thomas Dietze; Michael Möller; Wolfgang Schöbel; Jens Wicke; Hans-Jörg Kellner; Rainer Gradaus; Jörg Neuzner
Journal:  Clin Res Cardiol       Date:  2009-08-28       Impact factor: 5.460

2.  The subcutaneous defibrillator will replace the transvenous defibrillator.

Authors:  Ian Crozier
Journal:  J Interv Card Electrophysiol       Date:  2011-04-27       Impact factor: 1.900

Review 3.  Canadian Thoracic Society 2011 guideline update: diagnosis and treatment of sleep disordered breathing.

Authors:  John Fleetham; Najib Ayas; Douglas Bradley; Michael Fitzpatrick; Thomas K Oliver; Debra Morrison; Frank Ryan; Frederick Series; Robert Skomro; Willis Tsai
Journal:  Can Respir J       Date:  2011 Jan-Feb       Impact factor: 2.409

Review 4.  Central sleep apnea: Pathophysiology and treatment.

Authors:  Danny J Eckert; Amy S Jordan; Pankaj Merchia; Atul Malhotra
Journal:  Chest       Date:  2007-02       Impact factor: 9.410

5.  Cardiac memory in patients with Wolff-Parkinson-White syndrome: noninvasive imaging of activation and repolarization before and after catheter ablation.

Authors:  Subham Ghosh; Edward K Rhee; Jennifer N Avari; Pamela K Woodard; Yoram Rudy
Journal:  Circulation       Date:  2008-08-12       Impact factor: 29.690

6.  [Avoidance of ventricular pacing in patients with sinus node disease or intermittent AV block].

Authors:  U K H Wiegand
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2008-03

7.  In a swine model, chest compressions cause ventricular capture and, by means of a long-short sequence, ventricular fibrillation.

Authors:  Jose Osorio; Derek J Dosdall; Robert P Robichaux; Paul B Tabereaux; Raymond E Ideker
Journal:  Circ Arrhythm Electrophysiol       Date:  2008-09-13

8.  Recurrent Postmyocardial Infarction Ventricular Tachycardia: An Unusual Culprit.

Authors:  Akhil Kumar Sharma; Nirdesh Jain; Safal Safal; Vikas Kumar; Sudhanshu Kumar Dwivedi
Journal:  Case Rep Cardiol       Date:  2015-11-22

9.  High-resolution motion compensated MRA in patients with congenital heart disease using extracellular contrast agent at 3 Tesla.

Authors:  Darius Dabir; Claas Philip Naehle; Ralf Clauberg; Juergen Gieseke; Hans H Schild; Daniel Thomas
Journal:  J Cardiovasc Magn Reson       Date:  2012-10-29       Impact factor: 5.364

10.  A case of premature ventricular contractions, ventricular tachycardia, and arrhythmic storm induced by right ventricular pacing during cardiac resynchronization therapy: Electrophysiological mechanism and catheter ablation.

Authors:  Stefano Pedretti; Sara Vargiu; Marco Paolucci; Maurizio Lunati
Journal:  J Arrhythm       Date:  2015-07-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.