Literature DB >> 12834600

The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols.

S Affatato1, G Bersaglia, D Emiliani, I Foltran, P Taddei, M Reggiani, P Ferrieri, A Toni.   

Abstract

Ultra-high molecular-weight polyethylene (UHMWPE) has been used in total joint replacement for the last three decades. Despite the recent advancements in prosthesis design, the wear of UHMWPE remains a serious clinical problem; the release of wear debris may induce osteolysis and implant loosening. Controlling the quality of the polyethylene is essential to improve its wear resistance and any potential adverse effect caused by processing, manufacturing or sterilisation should be avoided. To evaluate the influence of the sterilisation method (gamma-irradiation and ethylene oxide (EtO)-treatment) and third-body particles, gamma- and EtO-sterilised UHMWPE acetabular cups were tested against CoCrMo femoral heads in a hip joint simulator run for 2.5million cycles in bovine calf serum in the presence of third-body polymethylmethacrylate (PMMA) particles. A method not requiring ultra-centrifugation has been proposed for the isolation of polyethylene wear debris from the serum lubricant. SEM analysis allowed debris shape and morphology to be determined, and the wear mechanism operating in this study to be hypothesised. The morphological features of the wear debris were in agreement with clinical findings, enabling the hip simulator function to be validated. Micro-Raman spectroscopy coupled to PLS analysis showed that the mechanical friction during in vitro tests induced significant crystallinity changes in all the cups. The most significant changes were observed for the EtO-sterilised cups, which showed the highest weight loss.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12834600     DOI: 10.1016/s0142-9612(03)00264-3

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  5 in total

1.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  On the assessment of oxidative and microstructural changes after in vivo degradation of historical UHMWPE knee components by means of vibrational spectroscopies and nanoindentation.

Authors:  Francisco J Medel; Clare M Rimnac; Steven M Kurtz
Journal:  J Biomed Mater Res A       Date:  2009-05       Impact factor: 4.396

Review 3.  Ultra high molecular weight polyethylene: mechanics, morphology, and clinical behavior.

Authors:  M C Sobieraj; C M Rimnac
Journal:  J Mech Behav Biomed Mater       Date:  2008-12-25

4.  Finite Element Simulations of Hard-On-Soft Hip Joint Prosthesis Accounting for Dynamic Loads Calculated from a Musculoskeletal Model during Walking.

Authors:  Alessandro Ruggiero; Massimiliano Merola; Saverio Affatato
Journal:  Materials (Basel)       Date:  2018-04-09       Impact factor: 3.623

5.  Development of a Novel in Silico Model to Investigate the Influence of Radial Clearance on the Acetabular Cup Contact Pressure in Hip Implants.

Authors:  Saverio Affatato; Massimiliano Merola; Alessandro Ruggiero
Journal:  Materials (Basel)       Date:  2018-07-25       Impact factor: 3.623

  5 in total