Measurement of polyethylene wear in total hip arthroplasty--accuracy versus ease of use.

Joon Soon Kang1, Seung Rim Park, Edward Ebramzadeh, Lawrence D Dorr.   

Abstract

The aim of this study was to compare the accuracy of four different methods for measuring wear using an apparatus that simulates known amounts of three dimensional wear. Wear was measured using the manual methods reported by Charnley, Livermore, Dorr and Wan and the computerized method reported by Devane. Only the method reported by Devane measured the three-dimensional (superior and anterior) wear with a reasonable accuracy, with a mean measurement error of 0.21 mm. With superior wear alone, Charnley's method underestimated the extent of wear by 16.6%, with a mean error of 0.35 mm; Livermore's method estimated wear to within 9.5%, with a mean error of 0.16 mm; Devane's method estimated wear to within 9.5%, with a mean error of 0.15 mm; and Dorr's method underestimated wear by 25.4%, with a mean error of 0.56 mm. Dorr's method was modified as a result of the experimental tests. The clinical application of the new method showed comparable data to that using the Devane method. In conclusion, this new method can be used to estimate the average wear in groups of patients accurately.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12833585     DOI: 10.3349/ymj.2003.44.3.473

Source DB:  PubMed          Journal:  Yonsei Med J        ISSN: 0513-5796            Impact factor:   2.759


  4 in total

1.  Analysis of polyethylene wear in plain radiographs.

Authors:  Maiken Stilling; Kjeld Søballe; Niels Trolle Andersen; Kristian Larsen; Ole Rahbek
Journal:  Acta Orthop       Date:  2009-12       Impact factor: 3.717

2.  A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up.

Authors:  Shijun Wang; ShuDong Zhang; YuChi Zhao
Journal:  J Orthop Surg Res       Date:  2013-07-08       Impact factor: 2.359

3.  A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up.

Authors:  Dean Pakvis; Liesbeth Biemond; Gijs van Hellemondt; Maarten Spruit
Journal:  Int Orthop       Date:  2010-09-05       Impact factor: 3.075

4.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.