Literature DB >> 12833223

Evaluation of a commercially available human C-reactive protein (CRP) turbidometric immunoassay for determination of canine serum CRP concentration.

Mads Kjelgaard-Hansen1, Asger Lundorff Jensen, Annemarie T Kristensen.   

Abstract

BACKGROUND: Serum C-reactive protein (CRP) is an acute phase marker in dogs that is useful for the diagnosis and monitoring of inflammatory disease. Rapid, reliable, and automated assays are preferable for routine evaluation of canine serum CRP concentration.
OBJECTIVE: The aim of this study was to evaluate whether canine serum CRP concentration could be measured reliably using an automated turbidometric immunoassay (TIA) designed for use with human serum.
METHODS: A commercially available TIA for human serum CRP (Bayer, Newbury, UK) was used to measure canine serum CRP concentration. Cross-reactivity of antigen was evaluated by the Ouchterlony procedure. Intra- and interassay imprecision was investigated by multiple measurements on canine serum samples and serum pools, respectively. Assay inaccuracy was investigated by linearity under dilution and comparison of methodologies (canine CRP ELISA, Tridelta Development Ltd, Kildare, UK). Then the assay was applied to serum samples from 14 clinically healthy dogs, 11 dogs with neoplasia, 13 with infections, 8 with endocrine or metabolic diseases, and 10 with miscellaneous diseases.
RESULTS: Cross-reactivity between canine serum CRP and the anti-human CRP antibody was found. Intra- and interassay imprecision ranged from 5.2% to 10.8% and 3.0% to 10.2%, respectively. Serum CRP concentration was measured in a linear and proportional manner. There was no significant disagreement and there was linear correlation of the results in the comparison of methodologies, except for a slight proportional discrepancy at low CRP concentrations (<10 microg/mL). Dogs with infections had a significantly higher concentration of serum CRP than did all other dogs, and dogs with neoplasia had a significantly higher concentration of serum CRP than did clinically healthy dogs.
CONCLUSIONS: Canine serum CRP concentration can be measured reliably using the commercially available TIA designed for human CRP.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12833223     DOI: 10.1111/j.1939-165x.2003.tb00319.x

Source DB:  PubMed          Journal:  Vet Clin Pathol        ISSN: 0275-6382            Impact factor:   1.180


  21 in total

Review 1.  Acute phase reactants, challenge in the near future of animal production and veterinary medicine.

Authors:  E Gruys; M J M Toussaint; N Upragarin; Ederen A M Van; A A Adewuyi; D Candiani; T K A Nguyen; J Sabeckiene
Journal:  J Zhejiang Univ Sci B       Date:  2005-10       Impact factor: 3.066

2.  Comparison of serum amyloid A and C-reactive protein as diagnostic markers of systemic inflammation in dogs.

Authors:  Michelle B Christensen; Rebecca Langhorn; Amelia Goddard; Eva B Andreasen; Elena Moldal; Asta Tvarijonaviciute; Jolle Kirpensteijn; Sabrina Jakobsen; Frida Persson; Mads Kjelgaard-Hansen
Journal:  Can Vet J       Date:  2014-02       Impact factor: 1.008

3.  Analytical and clinical validation of a time-resolved immunofluorometric assay (TR-IFMA) for canine C-reactive protein in serum.

Authors:  M D Parra; M Tuomola; J Cabezas-Herrera; J J Cerón
Journal:  Vet Res Commun       Date:  2006-02       Impact factor: 2.459

4.  Evaluation of the Randox and Fuji Dri-Chem vcCRP-P assays of canine C-reactive protein.

Authors:  Sung-Ah An; Ye-In Oh; Ul-Soo Choi; Jong-Bok Lee; Kyoung-Won Seo
Journal:  J Vet Diagn Invest       Date:  2022-07-06       Impact factor: 1.569

5.  Serum C-reactive protein and iron levels following gonadectomy are not modified by perioperative administration of robenacoxib to dogs.

Authors:  Verónica Vieitez; Victor López-Rámis; Rafael Barrera; Ignacio A Gómez de Segura
Journal:  Can J Vet Res       Date:  2022-01       Impact factor: 0.897

6.  Evaluation of an automated immunoturbidimetric assay for detecting canine C-reactive protein.

Authors:  Michele Berlanda; Carlotta Valente; Federico Bonsembiante; Tamara Badon; Silvia Bedin; Barbara Contiero; Carlo Guglielmini; Helen Poser
Journal:  J Vet Diagn Invest       Date:  2020-09-23       Impact factor: 1.279

7.  Use of serum C-reactive protein as an early marker of inflammatory activity in canine type II immune-mediated polyarthritis: case report.

Authors:  Mads Kjelgaard-Hansen; Asger Lundorff Jensen; Geoffrey A Houser; Lisbeth Rem Jessen; Annemarie T Kristensen
Journal:  Acta Vet Scand       Date:  2006-06-21       Impact factor: 1.695

8.  Decreased plasma Chromogranin A361-372 (Catestatin) but not Chromogranin A17-38 (Vasostatin) in female dogs with bacterial uterine infection (pyometra).

Authors:  Supranee Jitpean; Mats Stridsberg; Ann Pettersson; Odd V Höglund; Bodil Ström Holst; Ragnvi Hagman
Journal:  BMC Vet Res       Date:  2015-01-31       Impact factor: 2.741

9.  Validation of a commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein.

Authors:  Anna Hillström; Ragnvi Hagman; Harold Tvedten; Mads Kjelgaard-Hansen
Journal:  Vet Clin Pathol       Date:  2014-05-05       Impact factor: 1.180

10.  [Comparative safety study of two commercialised vaccines against canine babesiosis induced by Babesia canis].

Authors:  L Freyburger; L Lemaitre; C Médaille; F Oberli; L Fanchon; P Bergamo
Journal:  Parasite       Date:  2011-11       Impact factor: 3.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.