Literature DB >> 12831735

The fatigue strength of compact bone in torsion.

D Taylor1, P O'Reilly, L Vallet, T C Lee.   

Abstract

We have conducted a series of fatigue tests on samples of bovine compact bone loaded in cyclic torsion. The fatigue strength (i.e. the range of stress needed to cause failure in a given number of cycles) was found to be lower than the fatigue strength of the same material in compression by more than a factor of two. We also tested intact chicken metatarsals and found a similar reduction in strength compared to compression testing of chicken tibiae. These results were predicted using a theoretical model in which fatigue failure was assumed to be dependent on the growth of microcracks, oriented approximately parallel to the bone's longitudinal axis but having misorientation angles of up to 30 degrees. An effective stress range was derived which is a function of the normal and shear stresses, and thus of the Mode I and Mode II stress intensities experienced by the crack. These results may have important consequences for the understanding of fatigue in bone in vivo; relatively small amounts of longitudinal shear stress, which are often ignored in analysis, may contribute significantly to fatigue failures. This may shed light on the phenomenon of stress fractures and on the need for repair and adaptation in living bone.

Entities:  

Mesh:

Year:  2003        PMID: 12831735     DOI: 10.1016/s0021-9290(03)00104-0

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

Review 1.  The functional role of the ischiopubic membrane for the mechanical loading of the pubis in the domestic fowl (Gallus gallus).

Authors:  Regina Fechner; Matthias Stratmann; Rainer Gössling; Nina Sverdlova
Journal:  J Anat       Date:  2012-11-22       Impact factor: 2.610

2.  Orthopaedic magnetic resonance imaging challenge.

Authors:  Daniel Bodor; Mark H Awh; Michael E Stadnick
Journal:  Sports Health       Date:  2010-07       Impact factor: 3.843

3.  Dual-functional porous and cisplatin-loaded polymethylmethacrylate cement for reconstruction of load-bearing bone defect kills bone tumor cells.

Authors:  Zhule Wang; Liebert Parreiras Nogueira; Håvard Jostein Haugen; Ingrid Cm Van Der Geest; Patricia Caetano de Almeida Rodrigues; Dennis Janssen; Thom Bitter; Jeroen J J P van den Beucken; Sander Cg Leeuwenburgh
Journal:  Bioact Mater       Date:  2021-12-29

4.  Computed tomographic imaging of subchondral fatigue cracks in the distal end of the third metacarpal bone in the thoroughbred racehorse can predict crack micromotion in an ex-vivo model.

Authors:  Marie-Soleil Dubois; Samantha Morello; Kelsey Rayment; Mark D Markel; Ray Vanderby; Vicki L Kalscheur; Zhengling Hao; Ronald P McCabe; Patricia Marquis; Peter Muir
Journal:  PLoS One       Date:  2014-07-31       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.