Literature DB >> 12831734

Determining finger segmental centers of rotation in flexion-extension based on surface marker measurement.

Xudong Zhang1, Sang-Wook Lee, Peter Braido.   

Abstract

This paper describes the development of a novel algorithm for deriving finger segmental center of rotation (COR) locations during flexion-extension from measured surface marker motions in vivo. The algorithm employs an optimization routine minimizing the time-variance of the internal link lengths, and incorporates an empirically quantifiable relationship between the local movement of a surface marker around a joint (termed "surface marker excursion") and the joint flexion-extension. The latter relationship constrains and simplifies the optimization routine to make it computationally tractable. To empirically investigate this relationship and test the proposed algorithm, an experiment was conducted, in which hand cylinder-grasping movements were performed by 24 subjects (12 males and 12 females). Spherical retro-reflective markers were placed at various surface landmarks on the dorsal aspect of each subject's right (grasping) hand, and were measured during the movements by an opto-electronic system. Analysis of experimental data revealed a highly linear relationship between the "surface marker excursion" and the marker-defined flexion-extension angle: the average R(2) in linear regression ranged from 0.89 to 0.97. The algorithm successfully determined the CORs of the distal interphalangeal, proximal interphalangeal, and metacarpophalangeal joints of digits 2-5 during measured motions. The derived CORs appeared plausible as examined in terms of the physical locations relative to surface marker trajectories and the congruency across different joints and individuals.

Entities:  

Mesh:

Year:  2003        PMID: 12831734     DOI: 10.1016/s0021-9290(03)00112-x

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

1.  Fibonacci, littler, and the hand: a brief review.

Authors:  Alan L Hutchison; Richard L Hutchison
Journal:  Hand (N Y)       Date:  2010-04-08

2.  Comparison of two actuation systems for laparoscopic surgical manipulators using motion analysis.

Authors:  Yogesh Vinod Kolwadkar; Stuart I Brown; Rami J Abboud; Weijie Wang
Journal:  Surg Endosc       Date:  2010-08-24       Impact factor: 4.584

3.  Flexor digitorum profundus tendon tension during finger manipulation.

Authors:  Tatsuro Tanaka; Peter C Amadio; Chunfeng Zhao; Mark E Zobitz; Kai-Nan An
Journal:  J Hand Ther       Date:  2005 Jul-Sep       Impact factor: 1.950

4.  Robust identification of three-dimensional thumb and index finger kinematics with a minimal set of markers.

Authors:  Raviraj Nataraj; Zong-Ming Li
Journal:  J Biomech Eng       Date:  2013-09       Impact factor: 2.097

5.  Evidence for an internal model of friction when controlling kinetic energy at impact to slide an object along a surface toward a target.

Authors:  Sylvain Famié; Mehdi Ammi; Vincent Bourdin; Michel-Ange Amorim
Journal:  PLoS One       Date:  2022-02-24       Impact factor: 3.240

6.  Design and Evaluation of an Actuated Exoskeleton for Examining Motor Control in Stroke Thumb.

Authors:  Furui Wang; Christopher L Jones; Milind Shastri; Kai Qian; Derek G Kamper; Nilanjan Sarkar
Journal:  Adv Robot       Date:  2016-03-07       Impact factor: 1.699

7.  Integration of marker and force data to compute three-dimensional joint moments of the thumb and index finger digits during pinch.

Authors:  Raviraj Nataraj; Zong-Ming Li
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-08-15       Impact factor: 1.763

8.  Joint Angle Estimation of a Tendon-Driven Soft Wearable Robot through a Tension and Stroke Measurement.

Authors:  Byungchul Kim; Jiwon Ryu; Kyu-Jin Cho
Journal:  Sensors (Basel)       Date:  2020-05-17       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.