Literature DB >> 12831723

Prospective follow-up study of 95 patients with edentulous mandibles treated according to the Brånemark Novum concept.

Per Engstrand1, Kerstin Gröndahl, Lars-Olof Ohrnell, Peter Nilsson, Ulf Nannmark, Per-Ingvar Brånemark.   

Abstract

BACKGROUND: The long-term predictability reported with the traditional two-staged Brånemark method has led to developments aimed at simplifying the technique and reducing healing time. Results from a pilot study using the Brånemark Novum concept are promising, and it has been shown possible to fabricate and deliver an implant-supported fixed prosthesis to the patient on the day of surgery.
PURPOSE: The objective of this study is to report clinical and radiographic outcomes in a group of patients treated according to the Brånemark Novum concept.
MATERIALS AND METHODS: Ninety-five patients with edentulous mandibles were consecutively included in the study. Three specially designed fixtures were placed in each patient (285 fixtures in total) using drilling templates. The fixtures were immediately splinted with a prefabricated substructure, and fixed prostheses were delivered the same day in 67% of the patients. For the rest, prosthesis delivery ranged from 1 to 40 days (mean 5.6 d). Clinical and radiographic examinations were performed after 3 months, 6 months, 1 year, and then annually. The follow-up time was 1 to 5 years (mean 2.5 yr).
RESULTS: The cumulative prosthesis survival rate was 99%. Eighteen fixtures (6.3%) failed in 13 patients. Kaplan-Meier survival estimates demonstrated a probability implant survival at 1 year of 95.0% (94 patients), at 3 years of 93.3% (47 patients), and at 5 years of 93.3% (9 patients). The mean bone loss was 0.73 mm between the examinations at 3 months and 1 year, 0.16 mm during the second year, and 0.13 mm annually during years 3 to 5.
CONCLUSIONS: Comparable results, related to continuous prosthesis stability, were shown for the Novum approach compared with the traditional two-staged procedure. Survival of individual fixtures is lower when immediate loading is applied.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12831723     DOI: 10.1111/j.1708-8208.2003.tb00176.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Mechanical analysis of prosthetic bars and dental implants in 3 and 4 implant-supported overdenture protocols using finite element analysis.

Authors:  Luiz Bassi-Junior; Rafael Oliveira de Souza Silva; Victor Hugo Dias Dos Santos; Abner da Rocha Lourenço; Paulo Vinicius Trevizoli; Hugo Gaêta-Araujo; Polyane Mazucatto Queiroz; Vilmar Divanir Gottardo
Journal:  J Oral Biol Craniofac Res       Date:  2021-05-15

2.  A clinical study on the 6-year outcomes of immediately loaded three implants for completely edentulous mandibles: "the all-on-3 concept".

Authors:  Mustafa Ayna; Keyvan Sagheb; Ralf Gutwald; Henning Wieker; Christian Flörke; Yahya Açil; Jörg Wiltfang; Aydin Gülses
Journal:  Odontology       Date:  2019-07-05       Impact factor: 2.634

3.  A Study of Human Mandibles of Indian Origin for Available Bone After Bone Reduction for Trefoil Concept: A In-Vitro Human Cadaver Mandible Study.

Authors:  R Chowdhary; S Amber; N K Sonahalli
Journal:  J Maxillofac Oral Surg       Date:  2020-08-05

Review 4.  The use of three implants to support a fixed prosthesis in the management of the edentulous mandible: a systematic review.

Authors:  Murtaza Hirani; Maria Devine; Olamide Obisesan; Cathy Bryant
Journal:  Int J Implant Dent       Date:  2022-06-17

5.  Digital Smile Designed Computer-Aided Surgery versus Traditional Workflow in "All on Four" Rehabilitations: A Randomized Clinical Trial with 4-Years Follow-Up.

Authors:  Francesca Cattoni; Luca Chirico; Alberto Merlone; Michele Manacorda; Raffaele Vinci; Enrico Felice Gherlone
Journal:  Int J Environ Res Public Health       Date:  2021-03-26       Impact factor: 3.390

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.