Sampling rate effects on surface EMG timing and amplitude measures.

Jeffrey C Ives1, Janet K Wigglesworth.   

Abstract

OBJECTIVE: To determine if oversampling the surface electromyographic signal provides any benefit in analyzing common electromyographic timing and amplitude measures used in kinesiological studies.
DESIGN: A within subjects (n=8) repeated measures design was used to examine surface electromyographic signals captured under four contraction modes and acquired with five different analog-to-digital sampling rates.
BACKGROUND: There is a growing trend to sample surface electromyography at rates higher than the Nyquist rate. Though there is limited evidence to support oversampling, the necessity or benefit of doing so remains unclear.
METHODS: Surface electromyography was recorded from the triceps brachii during maximal, submaximal, and fatiguing isometric contractions, as well as dynamic contractions. The analog signals were bandpassed between 20 Hz and 2 kHz, and oversampled at 6 kHz. The signals were then digitally resampled at 3 kHz, 1 kHz, 500 Hz, and 250 Hz without benefit of an anti-aliasing filter. Amplitude and timing variables measured from both the rectified and smoothed signal were compared across sampling rates.
RESULTS: Oversampling produced no significant changes in timing and amplitude measures of the rectified or smoothed electromyographic signal. For the smoothed signal, minor undersampling at half the Nyquist rate was sufficient to accurately capture most timing and signal strength measures.
CONCLUSIONS: Oversampling is unnecessary to gather typical amplitude and timing measures from the surface electromyographic signal. Electromyography sampled below half the Nyquist rate is likely to result in a poor temporal and amplitude representation of the signal. RELEVANCE: Computer memory and processing resources for analyzing amplitude and timing information need not be expended in oversampling surface electromyography, and results of previous studies need not be outright dismissed because of minor undersampling violations or the lack of an anti-aliasing filter.

Mesh:

Year:  2003        PMID: 12828904     DOI: 10.1016/s0268-0033(03)00089-5

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  10 in total

1.  A spectral analysis of rotator cuff musculature electromyographic activity: surface and indwelling.

Authors:  Sherry I Backus; Daniel P Tomlinson; Bavornrat Vanadurongwan; Mark W Lenhoff; Frank A Cordasco; Eric L Chehab; Ronald S Adler; R Frank Henn; Howard J Hillstrom
Journal:  HSS J       Date:  2010-08-13

2.  Ranking hand movements for myoelectric pattern recognition considering forearm muscle structure.

Authors:  Youngjin Na; Sangjoon J Kim; Sungho Jo; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2017-01-04       Impact factor: 2.602

3.  Recording EMG Signals on a Computer Sound Card.

Authors:  Kevin M Crisp
Journal:  J Undergrad Neurosci Educ       Date:  2018-09-15

4.  Changes in surface EMG assessed by discrete wavelet transform during maximal isometric voluntary contractions following supramaximal cycling.

Authors:  Luis Peñailillo; Rony Silvestre; Kazunori Nosaka
Journal:  Eur J Appl Physiol       Date:  2012-09-23       Impact factor: 3.078

5.  The Relationship Between Submental Surface Electromyography and Hyo-Laryngeal Kinematic Measures of Mendelsohn Maneuver Duration.

Authors:  Alba M Azola; Lindsey R Greene; Isha Taylor-Kamara; Phoebe Macrae; Cheryl Anderson; Ianessa A Humbert
Journal:  J Speech Lang Hear Res       Date:  2015-12       Impact factor: 2.297

6.  Control strategies to re-establish glenohumeral stability after shoulder injury.

Authors:  Bala S Rajaratnam; James Ch Goh; Prem V Kumar
Journal:  BMC Sports Sci Med Rehabil       Date:  2013-12-06

Review 7.  Wearable technology in stroke rehabilitation: towards improved diagnosis and treatment of upper-limb motor impairment.

Authors:  Pablo Maceira-Elvira; Traian Popa; Anne-Christine Schmid; Friedhelm C Hummel
Journal:  J Neuroeng Rehabil       Date:  2019-11-19       Impact factor: 4.262

8.  Internet of Things for beyond-the-laboratory prosthetics research.

Authors:  Hancong Wu; Matthew Dyson; Kianoush Nazarpour
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2022-06-06       Impact factor: 4.019

9.  Corticospinal Excitability and Inhibition Are Not Different between Concussed Males and Females.

Authors:  Alexandra Pauhl; Alia Yasen; Anita Christie
Journal:  Brain Sci       Date:  2022-06-24

10.  An EEG Experimental Study Evaluating the Performance of Texas Instruments ADS1299.

Authors:  Usman Rashid; Imran Khan Niazi; Nada Signal; Denise Taylor
Journal:  Sensors (Basel)       Date:  2018-11-01       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.