Assessment of corneal thickness, intraocular pressure, optical corneal diameter, and axial globe dimensions in Miniature Horses.

Caryn E Plummer1, David T Ramsey, Joe G Hauptman.   

Abstract

OBJECTIVE: To determine corneal thickness, intraocular pressure (IOP), and horizontal and vertical corneal diameter (HCD and VCD) and to obtain axial measurements of the anterior chamber depth (ACD), crystalline lens thickness (CLT), vitreous chamber depth (VtCD), and axial globe length (AGL) in eyes of Miniature Horses. ANIMALS: 41 healthy Miniature Horses. PROCEDURE: Ocular component measurements were obtained via ultrasonic pachymetry, applanation tonometry, ultrasound, and by use of a Jameson caliper.
RESULTS: Mean IOP and corneal thickness for all eyes were 26.0 mm Hg and 785.6 microm, respectively. There was no correlation of age with IOP or corneal thickness and no difference in these variables between right and left eyes or between females and males. Mean HCD andVCD were 25.8 and 19.4 mm, respectively; although there were no differences between sexes or between right and left eyes, there was positive correlation of optical corneal diameters with increasing age. Mean ACD, CLT, VtCD, and AGL were smaller in Miniature Horses (5.6, 10.0, 18.1, and 33.7 mm, respectively), compared with values for full-sized horses; there was no difference in these variables between sexes or between right and left eyes in Miniature Horses, but they were correlated with increasing age. CONCLUSIONS AND CLINICAL RELEVANCE: In Miniature Horses, corneal thickness and IOP are similar to values reported for full-sized horses and do not increase with advancing age. Vertical corneal diameter, HCD, and AGL increase until 5, 7, and 2 years of age, respectively.

Entities:  

Mesh:

Year:  2003        PMID: 12828248     DOI: 10.2460/ajvr.2003.64.661

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  5 in total

1.  The precision of ophthalmic biometry using calipers.

Authors:  Ashik Mohamed; Derek Nankivil; Veerendranath Pesala; Mukesh Taneja
Journal:  Can J Ophthalmol       Date:  2013-12       Impact factor: 1.882

2.  Corneal thickness and anterior chamber depth of the normal adult horse as measured by ultrasound biomicroscopy.

Authors:  Kelly E Knickelbein; Mary E Lassaline; Soohyun Kim; Machal S Scharbrough; Sara M Thomasy
Journal:  Vet Ophthalmol       Date:  2022-01-27       Impact factor: 1.444

3.  Assessment of intraocular measurements in neonatal foals and association with gender, laterality, and body weight: a clinical study.

Authors:  Simona Valentini; Carolina Castagnetti; Vincenzo Musella; Giuseppe Spinella
Journal:  PLoS One       Date:  2014-10-08       Impact factor: 3.240

4.  The eye of the Barbary sheep or aoudad (Ammotragus lervia): reference values for selected ophthalmic diagnostic tests, morphologic and biometric observations.

Authors:  G A Fornazari; F Montiani-Ferreira; I R de Barros Filho; A T Somma; B Moore
Journal:  Open Vet J       Date:  2016-06-28

5.  Intraocular lens power calculation for the equine eye.

Authors:  Ulrike Meister; Christiane Görig; Christopher J Murphy; Hubertus Haan; Bernhard Ohnesorge; Michael H Boevé
Journal:  BMC Vet Res       Date:  2018-04-03       Impact factor: 2.741

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.