Literature DB >> 12827697

Isolation of monocytes from human peripheral blood using immuno-affinity expanded-bed adsorption.

L B Ujam1, R H Clemmitt, S A Clarke, R A Brooks, N Rushton, H A Chase.   

Abstract

A novel technique for the separation of monocytes from human peripheral blood preparations has been developed. The technique is based on the use of expanded-bed adsorption and a solid perfluorocarbon derivatized with avidin or streptavidin for the indirect positive or negative capture of cells labeled with biotinylated monoclonal antibodies. The perfluorocarbon support was prepared and characterized and the contactor design and operating conditions, that enable cells to be selectively isolated, were investigated. Experiments consisted of applying an immunolabeled pulse of 1 x 10(8) peripheral blood mononuclear cells (PBMCs), isolated by density gradient centrifugation, directly onto a refrigerated expanded bed. The major cell types remaining were T-lymphocytes, B-lymphocytes, and monocytes. Monocytes could be positively adsorbed, following labeling with anti-CD14 mAb, with a clearance of up to 89% and a depletion factor of 7.6. They could also be "eluted" using mechanical shear, with a 77% yield of the applied cells at a purity of 90% and >/= 65% viability. Negative isolation of monocytes, following labeling of the other cells present with anti-CD2, CD7, CD16, CD19, and CD56 mAbs, resulted in lymphocyte depletions of up to 81% with a monocyte enrichment factor of 3.8 and purity of 71%. The monocyte viability in the flowthrough was assessed to be > 95%. This combination of expanded-bed adsorption and fluidizable affinity supports shows significant potential for the intensification of cell separations. Copyright 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 83: 554-566, 2003.

Entities:  

Mesh:

Year:  2003        PMID: 12827697     DOI: 10.1002/bit.10703

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  7 in total

1.  Cell separation using cryogel-based affinity chromatography.

Authors:  Ashok Kumar; Akshay Srivastava
Journal:  Nat Protoc       Date:  2010-10-07       Impact factor: 13.491

2.  Efficient elusion of viable adhesive cells from a microfluidic system by air foam.

Authors:  Jr-Ming Lai; Hung-Jen Shao; Jen-Chia Wu; Si-Hong Lu; Ying-Chih Chang
Journal:  Biomicrofluidics       Date:  2014-08-13       Impact factor: 2.800

3.  Efficient release of immunocaptured cells using coiled-coils in a microfluidic device.

Authors:  Mengen Zhang; Bin Xu; Allison Siehr; Wei Shen
Journal:  RSC Adv       Date:  2019-09-17       Impact factor: 3.361

4.  Selective individual primary cell capture using locally bio-functionalized micropores.

Authors:  Jie Liu; Radoslaw Bombera; Loïc Leroy; Yoann Roupioz; Dieudonné R Baganizi; Patrice N Marche; Vincent Haguet; Pascal Mailley; Thierry Livache
Journal:  PLoS One       Date:  2013-03-01       Impact factor: 3.240

5.  Evaluation of a novel non-destructive catch and release technology for harvesting autologous adult stem cells.

Authors:  Nicholas Bryan; Fiona C Lewis; Damian Bond; Christopher Stanley; John A Hunt
Journal:  PLoS One       Date:  2013-01-22       Impact factor: 3.240

Review 6.  Micro- and nanotechnology in cell separation.

Authors:  Milica Radisic; Rohin K Iyer; Shashi K Murthy
Journal:  Int J Nanomedicine       Date:  2006

7.  Sensitive and Specific Biomimetic Lipid Coated Microfluidics to Isolate Viable Circulating Tumor Cells and Microemboli for Cancer Detection.

Authors:  Jia-Yang Chen; Wen-Sy Tsai; Hung-Jen Shao; Jen-Chia Wu; Jr-Ming Lai; Si-Hong Lu; Tsung-Fu Hung; Chih-Tsung Yang; Liang-Chun Wu; Jinn-Shiun Chen; Wen-Hwa Lee; Ying-Chih Chang
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.