Literature DB >> 12826974

Anesthesia during high-field intraoperative magnetic resonance imaging experience with 80 consecutive cases.

Bernd Schmitz1, Christopher Nimsky, Georg Wendel, Juergen Wienerl, Oliver Ganslandt, Klaus Jacobi, Rudolf Fahlbusch, Juergen Schüttler.   

Abstract

Intraoperative magnetic resonance imaging (MRI) has been used for years to update neuronavigation and for intraoperative resection control. For this purpose, low-field (0.1-0.2 T) MR scanners have been installed in the operating room, which, in contrast to machines using higher magnetic field strength, allowed the use of standard anesthetic and surgical equipment. However, these low-field MR systems provided only minor image quality and a limited battery of MR sequences, excluding functional MRI, diffusion-weighted MRI, or MR angiography and spectroscopy. Based on these advantages, a concept using high-field MRI (1.5 T) with intraoperative functional neuronavigational guidance has been developed that required adaptation of the anesthetic regimen to working in the close vicinity to the strong magnetic field. In this paper the authors present their experience with the first 80 consecutive patients who received anesthesia in a specially designed radio frequency-shielded operating room equipped with a high-field (1.5 T) MR scanner. We describe the MR-compatible anesthesia equipment used including ventilator, monitoring, and syringe pumps, which allow standard neuroanesthesia in this new and challenging environment. This equipment provides the use of total intravenous anesthesia with propofol and remifentanil allowing rapid extubation and neurologic examination following surgery. In addition, extended intraoperative monitoring including EEG monitoring required for intracranial surgery is possible. Moreover, problems and dangers related to the effects of the strong magnetic field are discussed.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12826974     DOI: 10.1097/00008506-200307000-00014

Source DB:  PubMed          Journal:  J Neurosurg Anesthesiol        ISSN: 0898-4921            Impact factor:   3.956


  2 in total

1.  Anesthetic challenges and outcomes for procedures in the intraoperative magnetic resonance imaging suite: A systematic review.

Authors:  Hedwig Schroeck; Tasha L Welch; Michelle S Rovner; Heather A Johnson; Florian R Schroeck
Journal:  J Clin Anesth       Date:  2018-11-08       Impact factor: 9.452

Review 2.  Intraoperative MRI in pediatric brain tumors.

Authors:  Asim F Choudhri; Adeel Siddiqui; Paul Klimo; Frederick A Boop
Journal:  Pediatr Radiol       Date:  2015-09-07