Literature DB >> 12826076

Water immersion and EMLA cause similar digit skin wrinkling and vasoconstriction.

Einar Wilder-Smith1, Adeline Chow.   

Abstract

Water immersion skin wrinkling tests limb sympathetic vasoconstrictor function. We have recently shown that water immersion wrinkling is accompanied by digit vasoconstriction and postulated that vasoconstriction is the main underlying mechanism. To test this further, we applied vasoconstrictive cream (EMLA) to the distal digit and compared the degree of skin wrinkling and digit blood flow reduction with those after water immersion. In 25 healthy volunteers (6 male, 19 female; mean age, 35 yr) subjected to EMLA and water immersion, both clinical wrinkling scores and reduction in digit blood flow (mean of 2.01 and 2.29 cm/s, respectively) were nearly identical. Control using aqueous cream resulted in minimal skin wrinkling and nonsignificant reduction in digit artery flow (P = 0.170). These data further support that water immersion skin wrinkling is mediated by vasoconstriction. The EMLA cream patch test may develop into a useful screening test for hand sympathetic vasoconstrictor function.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12826076     DOI: 10.1016/s0026-2862(03)00020-7

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  10 in total

1.  Examination of cardiovascular and peripheral autonomic function in the ICU: a pilot study.

Authors:  L Wieske; E R Kiszer; M J Schultz; C Verhamme; I N van Schaik; J Horn
Journal:  J Neurol       Date:  2012-12-30       Impact factor: 4.849

2.  The optimal duration for the wrinkle test in a clinical setting.

Authors:  Erez Grinbaum; Ahmad Shahwan; Amir Eliyahu; Ravit Shay; Nimrod Rozen; Guy Rubin
Journal:  Sci Rep       Date:  2022-05-25       Impact factor: 4.996

3.  EMLA cream does not influence efficacy and pain reduction during pulsed-dye laser treatment of port-wine stain: a prospective side-by-side comparison.

Authors:  Wenxin Yu; Tianyou Wang; Jiafang Zhu; Yajing Qiu; Hui Chen; Yunbo Jin; Xi Yang; Xiaojie Hu; Lei Chang; Yijie Chen; Gang Ma; Xiaoxi Lin
Journal:  Lasers Med Sci       Date:  2017-12-15       Impact factor: 3.161

4.  Water-induced finger wrinkles improve handling of wet objects.

Authors:  Kyriacos Kareklas; Daniel Nettle; Tom V Smulders
Journal:  Biol Lett       Date:  2013-01-08       Impact factor: 3.703

5.  Paradoxical response to water immersion in replanted fingers.

Authors:  Ching-Hua Hsieh; Kuo-Feng Huang; Po-Chou LiLiang; Seng-Feng Jeng; Hui-Hong Tsai
Journal:  Clin Auton Res       Date:  2006-04-12       Impact factor: 5.625

6.  Water-induced finger wrinkles do not affect touch acuity or dexterity in handling wet objects.

Authors:  Julia Haseleu; Damir Omerbašić; Henning Frenzel; Manfred Gross; Gary R Lewin
Journal:  PLoS One       Date:  2014-01-08       Impact factor: 3.240

7.  Efficiency of 90-Min Extended EMLA-Induced Stimulated Skin-Wrinkling Test in the Diagnosis of Carpal Tunnel Syndrome.

Authors:  Thomas John; Asha Elizabeth Mathew
Journal:  Ann Indian Acad Neurol       Date:  2021-12-07       Impact factor: 1.383

8.  The applicability of the digit wrinkle scan to quantify sympathetic nerve function.

Authors:  Maurice Sopacua; Carla M L Gorissen-Brouwers; Bianca T A de Greef; Isis B T Joosten; Catharina G Faber; Ingemar S J Merkies; Janneke G J Hoeijmakers
Journal:  Clin Neurophysiol Pract       Date:  2022-03-28

9.  EMLA-Induced Skin Wrinkling for the Detection of Diabetic Neuropathy.

Authors:  Kay Wei Ping Ng; Jonathan J Y Ong; Thaw Dar Nyein Nyein; Shen Liang; Yee Cheun Chan; Kok Onn Lee; Einar Patrick Wilder-Smith
Journal:  Front Neurol       Date:  2013-09-02       Impact factor: 4.003

10.  Early detection of peripheral neuropathy using stimulated skin wrinkling test in human immunodeficiency virus infected patients: A cross-sectional study.

Authors:  Arthur H P Mawuntu; Corry N Mahama; Herlyani Khosama; Riwanti Estiasari; Darma Imran
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.