Literature DB >> 12825033

Cost-effective initial screening for vestibular schwannoma: auditory brainstem response or magnetic resonance imaging?

Vedantam Rupa1, Anand Job, Mercy George, Vedantam Rajshekhar.   

Abstract

OBJECTIVE: Our goal was to determine the cost-effectiveness of including auditory brainstem response (ABR) testing in a screening protocol for the diagnosis of vestibular schwannoma (VS) in patients with asymmetric auditory symptoms at the Christian Medical College and Hospital, Vellore, India, where, commonly, patients with VS have tumors greater than 2 cm at the time of diagnosis.
METHODS: Ninety patients with asymmetric audiovestibular symptoms were investigated prospectively with both ABR and gadolinum-enhanced magnetic resonance imaging (GdMRI).
RESULTS: Of these 90 patients, 6 were diagnosed with VS on GdMRI. On ABR testing, 4 patients with VS had retrocochlear pathology and 2 with profound sensorineural hearing loss had no responses. ABR was found to have a sensitivity of 100% and specificity of 61.9%. A protocol involving screening of all patients with asymmetric audiovestibular symptoms using ABR and only subjecting those patients with no responses or retrocochlear pathology to GdMRI would effect a savings of $1200 for every patient detected to have a VS.
CONCLUSIONS: In our hospital setting, including ABR as the preliminary screen for patients with asymmetric audiovestibular symptoms is a cost-effective strategy.

Entities:  

Mesh:

Year:  2003        PMID: 12825033     DOI: 10.1016/S0194-59980300358-9

Source DB:  PubMed          Journal:  Otolaryngol Head Neck Surg        ISSN: 0194-5998            Impact factor:   5.591


  10 in total

1.  Syndromes of the orbital fissure, cavernous sinus, cerebello- pontine angle, and skull base.

Authors:  I Bone; D M Hadley
Journal:  J Neurol Neurosurg Psychiatry       Date:  2005-09       Impact factor: 10.154

Review 2.  Sudden sensorineural hearing loss: a review of diagnosis, treatment, and prognosis.

Authors:  Maggie Kuhn; Selena E Heman-Ackah; Jamil A Shaikh; Pamela C Roehm
Journal:  Trends Amplif       Date:  2011-05-22

3.  Analysis of Auditory Brainstem Response Change, according to Tinnitus Duration, in Patients with Tinnitus with Normal Hearing.

Authors:  Jae Woo Joo; Yong Jun Jeong; Mun Soo Han; Young-Soo Chang; Yoon Chan Rah; June Choi
Journal:  J Int Adv Otol       Date:  2020-08       Impact factor: 1.017

4.  Comparative evaluation of ABR abnormalities in patients with and without neurinoma of VIII cranial nerve.

Authors:  M Montaguti; C Bergonzoni; M A Zanetti; A Rinaldi Ceroni
Journal:  Acta Otorhinolaryngol Ital       Date:  2007-04       Impact factor: 2.124

5.  Auditory brainstem response prior to MRI compared to standalone MRI in the detection of vestibular schwannoma: A modelling study.

Authors:  Stan R W Wijn; Mayke A Hentschel; Andy J Beynon; Henricus P M Kunst; Maroeska M Rovers
Journal:  Clin Otolaryngol       Date:  2021-11-24       Impact factor: 2.729

Review 6.  Auditory Brainstem Responses in Tinnitus: A Review of Who, How, and What?

Authors:  Victoria Milloy; Philippe Fournier; Daniel Benoit; Arnaud Noreña; Amineh Koravand
Journal:  Front Aging Neurosci       Date:  2017-07-21       Impact factor: 5.750

Review 7.  Auditory Brainstem Responses (ABR) of Rats during Experimentally Induced Tinnitus: Literature Review.

Authors:  Ewa Domarecka; Heidi Olze; Agnieszka J Szczepek
Journal:  Brain Sci       Date:  2020-11-24

8.  Diagnostic Validity of Auditory Brainstem Response for the Initial Screening of Vestibular Schwannoma.

Authors:  Marn Joon Park; Joong Ho Ahn; Hong Ju Park; Jong Woo Chung; Woo Seok Kang
Journal:  J Audiol Otol       Date:  2021-10-29

Review 9.  Objective Detection of Tinnitus Based on Electrophysiology.

Authors:  Shuwen Fan; Shufeng Li
Journal:  Brain Sci       Date:  2022-08-16

10.  Comparison of 3 ABR Methods for Diagnosis of Retrocochlear Hearing Impairment.

Authors:  Krzysztof M Kochanek; Lech Śliwa; Marek Gołębiowski; Adam Piłka; Henryk Skarżyński
Journal:  Med Sci Monit       Date:  2015-12-07
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.