Literature DB >> 12822079

[Long-term results with the cementless CLS stem in hip replacement].

D Güther1, G Pap, P Bamert, S Eggli.   

Abstract

OBJECTIVE: The present work aims at evaluating the clinical and radiological long-term results of the cementless CLS stem in hip replacement.
METHOD: Sixty-six consecutively operated patients were examined clinically and radiologically at an average follow-up time of 10.7 (7.6 - 13.8) years. The clinical evaluation was done with the Merle d'Aubigné and the Harris hip scores. The radiological evaluation included the evaluation of radiolucencies as well as the occurrence of heterotopic ossifications.
RESULTS: A total of four stems had to be revised (two infections, two periprosthetic fractures). No stem revision had to be done because of aseptic loosening. This results in a survival rate of 94.5% according to Kaplan-Meier. The mean Merle d'Aubigné scores increased from 9.0 preoperatively to 16.0 points at follow-up. The mean follow-up Harris hip score was 87.3 points. Periprothetic osteolytic zones were observed in 45% of the cases, particularly in the Gruen zones 1 and 7. These osteolytic zones were mainly found in connection with cementless polyethylene cups.
CONCLUSION: The results of this study confirm the positive short and medium-term results with the CLS stem in a long-term process. The formerly described phenomenon of the residual thigh pain with cementless stems was clearly minimized.

Entities:  

Mesh:

Year:  2003        PMID: 12822079     DOI: 10.1055/s-2003-40080

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  3 in total

1.  Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data.

Authors:  Patrick Sadoghi; Wolfgang Janda; Mark Agreiter; Rauend Rauf; Andreas Leithner; Gerold Labek
Journal:  Int Orthop       Date:  2013-03-24       Impact factor: 3.075

2.  Long-term (20- to 25-year) results of an uncemented tapered titanium femoral component and factors affecting survivorship.

Authors:  Marcus R Streit; Moritz M Innmann; Christian Merle; Thomas Bruckner; Peter R Aldinger; Tobias Gotterbarm
Journal:  Clin Orthop Relat Res       Date:  2013-05-14       Impact factor: 4.176

Review 3.  Early subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.

Authors:  Paul van der Voort; Bart G Pijls; Marc J Nieuwenhuijse; Jorrit Jasper; Marta Fiocco; Josepha W M Plevier; Saskia Middeldorp; Edward R Valstar; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2015       Impact factor: 3.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.