| Literature DB >> 12818693 |
A Radi1.
Abstract
A voltammetric method was described for the determination of pantoprazole by differential-pulse adsorptive stripping voltammetry at a carbon paste electrode. Accumulation of pantoprazole was found to be optimized in Britton-Robinson buffer (0.04 M, pH 4.0) solution following 5 min accumulation time at open circuit condition. Under optimized conditions, the current showed a linear dependence with concentration in the range 1.0 x 10(-7)-1.0 x 10(-5) M. The detection limit was 2.0 x 10(-8) M. The method was applied successfully for the analysis of pantoprazole in tablet dosage form. The results of accuracy and precision were comparable to those obtained by spectrophotometry.Entities:
Mesh:
Substances:
Year: 2003 PMID: 12818693 DOI: 10.1016/S0014-827X(03)00082-X
Source DB: PubMed Journal: Farmaco ISSN: 0014-827X