Peri-implant soft tissue integration of immediately loaded implants in the posterior macaque mandible: a histomorphometric study.

Chong Huat Siar1, Chooi Gait Toh, George Romanos, Dasan Swaminathan, Ah Hup Ong, Hashim Yaacob, Georg-Hubertus Nentwig.   

Abstract

BACKGROUND: Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
METHODS: Splinted crowns on screw-shaped titanium implants (8 mm length, 3.5 mm diameter) were utilized. Three implants each were placed in the premolar-molar edentulous mandibular segments of 6 adult monkeys (Macaca fascicularis); one side served as the control (delayed loading) and the other as the test sites (immediate loading). The animals were sacrificed after 3 months of loading. Histomorphometry of 6 soft tissue indices including the sulcus depth (SD), junctional epithelium (JE), connective tissue contact (CTC), biologic width (BW = SD + JE + CTC), DIM (distance between the implant top and coronal gingiva), and DIB (distance between the implant top and first implant-to-bone contact) was performed on non-decalcified sections.
RESULTS: No significant differences in the mean soft tissue scores (mm) between the test (SD = 0.68 +/- 0.63; JE = 1.71 +/- 1.04; CTC = 1.51 +/- 1.14; DIM = 2.27 +/- 1.18; DIB = 1.32 +/- 1.21; BW = 3.9) and control (SD = 0.88 + 0.57; JE = 1.66 + 0.77; CTC = 1.24 +/- 0.92; DIM = 2.38 +/- 0.81; DIB = 1.19 +/- 0.91; BW = 3.78) groups were observed (P > 0.01).
CONCLUSION: These findings suggest that the dimensions of the peri-implant soft tissues were within the biologic range and were not influenced by immediate functional loading or posterior location of the implants in the macaque mandible.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12816287     DOI: 10.1902/jop.2003.74.5.571

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  5 in total

1.  Comparative study of immediate functional loading and immediate non-functional loading of monocortical implants.

Authors:  J P Singh; A K Gupta; R K Dhiman; S K Roy Chowdhury
Journal:  Med J Armed Forces India       Date:  2014-03-12

2.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

3.  Clinician- and patient-reported long-term evaluation of screw- and cement-retained implant restorations: a 5-year prospective study.

Authors:  Sami Sherif; Srinivas M Susarla; Jae-Woong Hwang; Hans-Peter Weber; Robert F Wright
Journal:  Clin Oral Investig       Date:  2010-09-01       Impact factor: 3.573

4.  Biological width around one- and two-piece implants retrieved from human jaws.

Authors:  Ricardo Judgar; Gabriela Giro; Elton Zenobio; Paulo G Coelho; Magda Feres; Jose A Rodrigues; Carlo Mangano; Giovanna Iezzi; Adriano Piattelli; Jamil Awad Shibli
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

5.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06