Literature DB >> 12815649

An inductively-coupled, detachable receiver coil system for use with magnetic resonance compatible endoscopes.

David J Gilderdale1, Andreanna D Williams, Umakant Dave, Nandita M deSouza.   

Abstract

PURPOSE: To construct an inductively-coupled receiver coil system for use with a magnetic resonance (MR) compatible endoscope, and to evaluate its use in a pilot group of patients with esophageal cancer.
MATERIALS AND METHODS: An inductively-coupled coil system, comprising a saddle geometry cylindrical receiver coil fitted as a sleeve around the endoscope tip and a pick-up coil housed within a channel of an MR-compatible endoscope, was designed and developed for use at 0.5 T. Twenty-three patients with esophageal cancer were recruited for MR endoscopy. In 17 cases, the endoscopic coil system was used in conjunction with an external surface coil in order to obtain information from the surrounding mediastinum. The examination took 40-50 minutes.
RESULTS: MR imaging using the inductively-coupled endoscopic coil was successful in 21 cases (one failed intubation and one artifact from unrelated external source). Image artifact was largely due to respiration and global patient motion in sedated individuals undergoing endoscopy.
CONCLUSION: Inductively-coupled coil systems may be used with endoscopes to allow improved safety through increased patient-system isolation and detachability of coils and electronics for repair or replacement with coils tuned for different frequencies. Copyright 2003 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2003        PMID: 12815649     DOI: 10.1002/jmri.10321

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

1.  MR-guided biopsies with a newly designed cordless coil in an open low-field system: initial findings.

Authors:  Stephan Zangos; Theodor Vetter; Frank Huebner; Montu Tuwari; Florian Mayer; Katrin Eichler; M-L Hansmann; A Wetter; C Herzog; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-12-13       Impact factor: 5.315

2.  In Vitro Intraductal MRI and T2 Mapping of Cholangiocarcinoma Using Catheter Coils.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Richard R A Syms
Journal:  Hepat Med       Date:  2020-07-27

3.  Endoluminal MR imaging of porcine gastric structure in vivo.

Authors:  Hayato Yoshinaka; Yoshinori Morita; Yuichiro Matsuoka; Daisuke Obata; Shoko Fujiwara; Ryo Chinzei; Maki Sugimoto; Tsuyoshi Sanuki; Masaru Yoshida; Hideto Inokuchi; Etsuko Kumamoto; Kagayaki Kuroda; Takeshi Azuma; Hiromu Kutsumi
Journal:  J Gastroenterol       Date:  2010-01-20       Impact factor: 7.527

4.  A Micro Saddle Coil with Switchable Sensitivity for Local High-Resolution Imaging of Luminal Tissue.

Authors:  Tetsuji Dohi; Kousuke Murashige
Journal:  Micromachines (Basel)       Date:  2016-04-21       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.