Literature DB >> 12814247

Independence of myoelectric control signals examined using a surface EMG model.

Madeleine M Lowery1, Nikolay S Stoykov, Todd A Kuiken.   

Abstract

The detection volume of the surface electromyographic (EMG) signal was explored using a finite-element model, to examine the feasibility of obtaining independent myoelectric control signals from regions of reinnervated muscle. The selectivity of the surface EMG signal was observed to decrease with increasing subcutaneous fat thickness. The results confirm that reducing the interelectrode distance or using double-differential electrodes can increase surface EMG selectivity in an inhomogeneous volume conductor. More focal control signals can be obtained, at the expense of increased variability, by using the mean square value, rather than the root mean square or average rectified value.

Mesh:

Year:  2003        PMID: 12814247     DOI: 10.1109/TBME.2003.812152

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  7 in total

Review 1.  Surface electromyogram signal modelling.

Authors:  K C McGill
Journal:  Med Biol Eng Comput       Date:  2004-07       Impact factor: 2.602

2.  Improved myoelectric prosthesis control using targeted reinnervation surgery: a case series.

Authors:  Laura A Miller; Kathy A Stubblefield; Robert D Lipschutz; Blair A Lock; Todd A Kuiken
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2008-02       Impact factor: 3.802

3.  The effects of electrode size and orientation on the sensitivity of myoelectric pattern recognition systems to electrode shift.

Authors:  Aaron J Young; Levi J Hargrove; Todd A Kuiken
Journal:  IEEE Trans Biomed Eng       Date:  2011-06-09       Impact factor: 4.538

4.  Anatomically accurate model of EMG during index finger flexion and abduction derived from diffusion tensor imaging.

Authors:  Diego Pereira Botelho; Kathleen Curran; Madeleine M Lowery
Journal:  PLoS Comput Biol       Date:  2019-08-29       Impact factor: 4.475

5.  Hard-wired Epimysial Recordings from Normal and Reinnervated Muscle Using a Bone-anchored Device.

Authors:  Henry T Lancashire; Yazan Al Ajam; Robert P Dowling; Catherine J Pendegrass; Gordon W Blunn
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-09-23

6.  A Finite Element Model Approach to Determine the Influence of Electrode Design and Muscle Architecture on Myoelectric Signal Properties.

Authors:  A Teklemariam; E F Hodson-Tole; N D Reeves; N P Costen; G Cooper
Journal:  PLoS One       Date:  2016-02-17       Impact factor: 3.240

7.  Analysis and Biophysics of Surface EMG for Physiotherapists and Kinesiologists: Toward a Common Language With Rehabilitation Engineers.

Authors:  Lara McManus; Giuseppe De Vito; Madeleine M Lowery
Journal:  Front Neurol       Date:  2020-10-15       Impact factor: 4.003

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.