Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

Byung Il Lee1, Suk Hoon Oh, Eung Je Woo, Soo Yeol Lee, Min Hyeong Cho, Ohin Kwon, Jin Keun Seo, Woon Sik Baek.   

Abstract

In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a static resistivity image of a cubic saline phantom (50 x 50 x 50 mm3) containing a cylindrical sausage object with an average resistivity value of 123.7 ohms cm. Our current MREIT system is based on an experimental 0.3 T MRI scanner and a current injection apparatus. We captured MR phase images of the phantom while injecting currents of 28 mA through two pairs of surface electrodes. We computed current density images from magnetic flux density images that are proportional to the MR phase images. From the current density images and boundary voltage data we reconstructed a cross-sectional resistivity image within a central region of 38.5 x 38.5 mm2 at the middle of the phantom using the J-substitution algorithm. The spatial resolution of the reconstructed image was 64 x 64 and the reconstructed average resistivity of the sausage was 117.7 ohms cm. Even though the error in the reconstructed average resistivity value was small, the relative L2-error of the reconstructed image was 25.5% due to the noise in measured MR phase images. We expect improvements in the accuracy by utilizing an MRI scanner with higher SNR and increasing the size of voxels scarifying the spatial resolution.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12812440     DOI: 10.1088/0967-3334/24/2/367

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  3 in total

1.  High field MREIT: setup and tissue phantom imaging at 11 T.

Authors:  Rosalind Sadleir; Samuel Grant; Sung Uk Zhang; Suk Hoon Oh; Byung Il Lee; Eung Je Woo
Journal:  Physiol Meas       Date:  2006-04-24       Impact factor: 2.833

2.  Induced current magnetic resonance electrical impedance tomography of brain tissues based on the J-substitution algorithm: a simulation study.

Authors:  Yang Liu; Shanan Zhu; Bin He
Journal:  Phys Med Biol       Date:  2009-06-26       Impact factor: 3.609

3.  Reconstruction of dual-frequency conductivity by optimization of phase map in MREIT and MREPT.

Authors:  Oh In Kwon; Woo Chul Jeong; Saurav Z K Sajib; Hyung Joong Kim; Eung Je Woo; Tong In Oh
Journal:  Biomed Eng Online       Date:  2014-03-08       Impact factor: 2.819