Literature DB >> 12812430

Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms.

Robert P Patterson1, Jie Zhang.   

Abstract

A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs of adjacent positions were excited sequentially by injecting current in a manner similar to that used by the Sheffield DAS-01P EIT system. The resulting voltages on the non-excited electrode positions were calculated and used to reconstruct the image using the Sheffield filtered back projection algorithm. By changing the resistivities of the lungs, the ventricles and the atria over a range of 1% to 40%, the resulting changes in the images were quantified by measuring the average resistivity change over a region defined automatically by two thresholds, 40% or 80% of the average of the first four pixels with the largest change. The results show that the changes observed in the images are consistently less than the changes in the model, but changed in a nearly linear manner as a function of resistivity in the model. For 40% resistivity changes in the model for right lung, right ventricle and right atrium, the observed resistivity changes in the region of interest (ROI, defined by the 80% threshold) of the images are 32% for the right lung, 11% for the right ventricle and 5.5% for the right atrium, which suggests strong volume dependence of EIT imaging. The effect of structural (size) change between end diastole and end systole was also studied, which showed large resistivity changes caused in the heart region of the constructed image. The study demonstrates that the Sheffield DAS-01P EIT reconstruction algorithm tracks the change occurring in the lungs most closely and with proper scaling may be used to observe physiological changes.

Entities:  

Mesh:

Year:  2003        PMID: 12812430     DOI: 10.1088/0967-3334/24/2/357

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Optimizing bioimpedance measurement configuration for dual-gated nuclear medicine imaging: a sensitivity study.

Authors:  Tuomas Koivumäki; Marko Vauhkonen; Jyrki T Kuikka; Mikko A Hakulinen
Journal:  Med Biol Eng Comput       Date:  2011-05-27       Impact factor: 2.602

2.  Modelling of an oesophageal electrode for cardiac function tomography.

Authors:  J Nasehi Tehrani; C Jin; A L McEwan
Journal:  Comput Math Methods Med       Date:  2012-03-15       Impact factor: 2.238

3.  Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography.

Authors:  Jie Zhang; Lihong Qin; Tadashi Allen; Robert P Patterson
Journal:  Open Biomed Eng J       Date:  2013-11-15

4.  Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.

Authors:  Jie Zhang; Robert Patterson
Journal:  Open Biomed Eng J       Date:  2014-06-27

5.  A MATLAB-Based Boundary Data Simulator for Studying the Resistivity Reconstruction Using Neighbouring Current Pattern.

Authors:  Tushar Kanti Bera; J Nagaraju
Journal:  J Med Eng       Date:  2013-05-28

6.  Low Power Contactless Bioimpedance Sensor for Monitoring Breathing Activity.

Authors:  Marko Pavlin; Franc Novak; Gregor Papa
Journal:  Sensors (Basel)       Date:  2021-03-16       Impact factor: 3.576

  6 in total