In vitro validation of an ultrasonic flowmeter in order to measure the functional residual capacity in newborns.

Juliane Wauer1, Tim U Leier, Matthias Henschen, Roland R Wauer, Gerd Schmalisch.   

Abstract

Ultrasonic transit-time airflow meters (UFM) allow simultaneous measurements of volume flow V'(t) and molar mass MM(t) of the breathing gas in the mainstream. Consequently, by using a suitable tracer gas the functional residual capacity (FRC) of the lungs can be measured by a gas wash-in/wash-out technique. The aim of this study was to investigate the in vitro accuracy of a multiple-breath wash-in/wash-out technique for FRC measurements using 4% sulphur hexafluoride (SF6) in air. V'(t) and MM(t) were measured with a Spiroson SCIENTIFIC flowmeter (ECO Medics, CH) with 1.3 ml dead space. Linearity of airflow and MM were tested using different tidal volumes (V(T)) and breathing gases with different O2 and SF6 concentrations. To determine the accuracy of FRC measurements SF6 wash-in and wash-out curves from four mechanical lung models (FRC of 22, 53, 102 and 153 ml) were evaluated by the Spiroson. For each model five measurements were performed with a physiological V(T)/FRC ratio of 0.3 and constant respiratory rate of 30 min(-1). The error of measured V(T) (range 4-60 ml) was <2.5%. There was a strong correlation between the measured and calculated MM of different breathing gases (r = 0.989), and the measuring accuracy was better than 1%. The measured FRC of the four models were 20.3, 49.7, 104.3 and 153.4 ml with a coefficient of variation of 16.5%, 4.5%, 4.9% and 3%. Accordingly, for FRC <100 ml the in vitro accuracy was better than 8% and for FRC >100 ml better than 2.5%. The determination of FRC by MM measurements using the UFM is a simple and cost-effective alternative to conventionally used gas analysers with an acceptable accuracy for many clinical purposes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12812421     DOI: 10.1088/0967-3334/24/2/311

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  2 in total

1.  Measurement of lung volume in mechanically ventilated monkeys with an ultrasonic flow meter and the nitrogen washout method.

Authors:  Andreas Schibler; Jürg Hammer; Ruedi Isler; Christian Buess; Christopher J L Newth
Journal:  Intensive Care Med       Date:  2003-10-07       Impact factor: 17.440

2.  A realistic validation study of a new nitrogen multiple-breath washout system.

Authors:  Florian Singer; Birgitta Houltz; Philipp Latzin; Paul Robinson; Per Gustafsson
Journal:  PLoS One       Date:  2012-04-27       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.