The effect of different power densities and method of exposure on the marginal adaptation of four light-cured dental restorative materials.

Theunis G Oberholzer1, Cornelis H Pameijer, Sias R Grobler, Roelof J Rossouw.   

Abstract

PURPOSE: To determine whether marginal adhesion is sensitive to different irradiation parameters, we investigated the in vitro adhesion values of four dental resins on metal surfaces.
METHODS: Four groups of eight specimens each of Z250, Filtek flow, Dyract AP and Dyract flow were placed in pre-treated stainless steel cavities and irradiated using different methods of exposure. The curing lights used were a Spectrum 800 halogen curing light at settings of 800 and 450 mW/cm(2) and an Optilux 501 ramping light. The maximum amount of push-out force required to displace the resin from the metal cavity was equated with adhesive value (shear bond strength). Comparisons (ANOVA, p<0.0001) were made within the same material and between the different materials when using different curing protocols.
RESULTS: Significant lower bond strengths were recorded when curing was done by gradually increasing the intensity (ramping method) compared to curing with the fixed intensities (p>0.0001) Comparing the fixed intensities, significant lower bond strength values were obtained at 800 mW/cm(2) compared to 450 mW/cm(2) (p<0.0001). For all exposures, the two flowable materials demonstrated weaker values when compared to the higher filled materials. CLINICAL SIGNIFICANCE: The advantage of initial slow polymerization (more elasticity and less tension) obtained by the so-called "soft start" method, was offset by a rise in total polymerization shrinkage, when final curing was completed at 1130 mW/cm(2). These tests demonstrated that using halogen units, exposure for 40s with an intensity of 450 mW/cm(2) appeared to be the most promising for light-curing dental resin composites.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12809788     DOI: 10.1016/s0142-9612(03)00211-4

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  2 in total

1.  Effect of diode-pumped solid state laser on polymerization shrinkage and color change in composite resins.

Authors:  Yun-Hoa Jung; Bong-Hae Cho; Kyung-Soo Nah; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2009-02-10       Impact factor: 3.161

2.  Clinical performance of resin-modified glass ionomer cement, flowable composite, and polyacid-modified resin composite in noncarious cervical lesions: One-year follow-up.

Authors:  Syed Nazia Hussainy; Iffat Nasim; Toby Thomas; Manish Ranjan
Journal:  J Conserv Dent       Date:  2018 Sep-Oct