Literature DB >> 12808542

The accuracy of needle placement in lower-limb muscles: a blinded study.

Andrew J Haig1, Craig W Goodmurphy, Albert R Harris, Alejandro Perez Ruiz, Jeffery Etemad.   

Abstract

OBJECTIVE: To assess the accuracy of common anatomic guides for electromyographic needle placement in muscles.
DESIGN: Blinded study. The dissector identified different needle placements by a random number attached to a wire in the insertion site.
SETTING: A university anatomy laboratory. CADAVERS: Ten cadaver lower limbs.
INTERVENTIONS: By using techniques published in texts by Gieringer and Delagi and Perotto, clinical electromyographers palpated and measured appropriate locations for needle placement. A thin wire was inserted through the needle into 36 different muscles in 10 cadavers, resulting in 263 targeted muscles. An anatomist blinded to intended location dissected and recorded muscles and other tissues that the wire pierced or passed near. MAIN OUTCOME MEASURES: Targeted muscle penetration, final resting place of the wire tip, and proximity to vital structures.
RESULTS: Fifty-seven percent of insertions penetrated the intended muscle. The wire tip was in the intended muscle 45% of the time. Seventeen percent of insertions penetrated or passed within 5mm of an important structure, including nerve (9.1%), tendon (3.0%), named artery (2.7%), vein (2.7%), or joint (0.8%). Specific muscle accuracy was highly variable, from 0% for 12 tries in various deep hip muscles to 100% of 10 tries in the vastus medialis.
CONCLUSION: The accuracy of blind needle placement varied according to muscle. With the blind insertion technique, more accurate and safe needle placement strategies can be developed.

Mesh:

Year:  2003        PMID: 12808542     DOI: 10.1016/s0003-9993(03)00014-5

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  12 in total

1.  Accuracy of non-guided versus ultrasound-guided injections in cervical muscles: a cadaver study.

Authors:  Alexandre Kreisler; Camille Gerrebout; Luc Defebvre; Xavier Demondion
Journal:  J Neurol       Date:  2021-01-05       Impact factor: 4.849

2.  Resident Accuracy of Electromyography Needle Electrode Placement Using Ultrasound Verification.

Authors:  Kristopher Karvelas; Craig Ziegler; Monica E Rho
Journal:  PM R       Date:  2015-12-12       Impact factor: 2.298

3.  Comparison of surface and ultrasound localization to identify forearm flexor muscles for botulinum toxin injections.

Authors:  M Kristi Henzel; Michael C Munin; Christian Niyonkuru; Elizabeth R Skidmore; Douglas J Weber; Ross D Zafonte
Journal:  PM R       Date:  2010-07       Impact factor: 2.298

4.  Ultrasound combined with electrodiagnosis improves lesion localization and outcome in posterior interosseous neuropathy.

Authors:  Yevgeniya Dvorkin Wininger; Neilly A Buckalew; Robert A Kaufmann; Michael C Munin
Journal:  Muscle Nerve       Date:  2015-09-10       Impact factor: 3.217

5.  Clinical Consensus on Diagnosis and Treatment of Patients with Chronic Exertional Compartment Syndrome of the Leg: A Delphi Analysis.

Authors:  Sanne Vogels; E D Ritchie; B L S Borger van der Burg; M R M Scheltinga; W O Zimmermann; R Hoencamp
Journal:  Sports Med       Date:  2022-07-29       Impact factor: 11.928

6.  Improvement of lower extremity electrodiagnostic findings following a trial of spinal manipulation and motion-based therapy.

Authors:  Mark W Morningstar
Journal:  Chiropr Osteopat       Date:  2006-09-12

7.  Accuracy of needle placement in cadavers: non-guided versus ultrasound-guided.

Authors:  Jae Sung Yun; Min Jae Chung; Hae Rim Kim; Jae In So; Jung Eun Park; Hyun Mi Oh; Jong In Lee
Journal:  Ann Rehabil Med       Date:  2015-04-24

8.  Ultrasonographic Evaluation of Three Approaches for Botulinum Toxin Injection into Tibialis Posterior Muscle in Chronic Stroke Patients with Equinovarus Foot: An Observational Study.

Authors:  Stefania Spina; Salvatore Facciorusso; Chiara Botticelli; Domenico Intiso; Maurizio Ranieri; Antonio Colamaria; Pietro Fiore; Chiara Ciritella; François Genêt; Andrea Santamato
Journal:  Toxins (Basel)       Date:  2021-11-22       Impact factor: 4.546

9.  Study protocol: precision of a protocol for manual intramuscular needle placement checked by passive stretching and relaxing of the target muscle in the lower extremity during BTX-A treatment in children with spastic cerebral palsy, as verified by means of electrical stimulation.

Authors:  Jessica Warnink-Kavelaars; Roland Jeroen Vermeulen; Jules Guilhelmus Becher
Journal:  BMC Pediatr       Date:  2013-08-22       Impact factor: 2.125

10.  Optimal Needle Placement for Extensor Hallucis Longus Muscle: A Cadaveric Study.

Authors:  In Yae Cheong; Do Kyun Kim; Ye Jeong Oh; Byung Kyu Park; Ki Hoon Kim; Dong Hwee Kim
Journal:  Ann Rehabil Med       Date:  2016-06-29