Literature DB >> 12807039

Less invasive stabilization system (LISS) in the treatment of distal femoral fractures.

M Schütz1, M Müller, M Kääb, N Haas.   

Abstract

The treatment of distal femoral fractures has been associated with a high rate of complications for a long time. Although implants and surgical techniques have improved, plate osteosynthesis and intramedullary nailing have been accompanied by a high occurrence of infection, non-union and malalignment. The treatment of soft tissue envelopes using "biological" osteosynthesis and minimally invasive approaches has resulted in a decrease in complication rates and ultimately led to the concept of the less invasive stabilization system (LISS). This is an extramedullary-applied, internal fixator shaped according to the implantation site anatomy, with minimal invasiveness. The purpose of this study was to present this new surgical technique and draw attention to its advantages and importance. Although this is not a scientific paper, we hope to provide enough evidence of the LISS usefulness. The main LISS components include multiple-fixed angle screws and an insertion handle for submuscular sliding of a fixator and placement of percutaneous, self-drilling, unicortical screws for fixation of the diaphyseal fracture fragments. The LISS has been designed to preserve periosteal perfusion and to facilitate a minimally invasive application. Since the first implantation of the LISS, only a few studies have been published on its use in treatment of distal femoral fractures. The rate of infection has been low, ranging from 0 to 4%. The rate of delayed union has been between 2.4 and 6.1%, but delayed unions do not necessarily lead to secondary bone grafting or repeat osteosynthesis as the LISS has a high and lasting stability. When the LISS is used, bone grafting is rarely necessary (0 to 1.6% in primary and 0 to 5% in secondary grafting). Also implant failure differs from the failure of plate osteosynthesis because, with the use of LISS, no screw loosening or secondary malalignment occurs. Implant failures (up to 7.4%) were recorded particularly at the time of LISS introduction in surgical practice and were attributed to the technique of implantation rather than to the implant itself. Good treatment outcomes have been reported. The average knee flexion has been 103 degrees and 107 degrees. In 72.5% of the patients, flexion has been more than 90 degrees and an extension lag of > or = 10 degrees has been found in only 7.5% of all cases. The average Neer score has ranged from 73.9 to 77.2 points. In conclusion, the LISS is a useful implant for treatment of distal femoral fractures, especially when bone quality is poor. Infection, delayed union and non-union rates are low, as shown by yet unpublished data from our clinic. Primary bone grafting, which is rarely necessary with this system, is carried out only when there is a great bone loss. Implant failure, such as screw loosening or secondary malalignment, is not seen.

Entities:  

Mesh:

Year:  2003        PMID: 12807039

Source DB:  PubMed          Journal:  Acta Chir Orthop Traumatol Cech        ISSN: 0001-5415            Impact factor:   0.531


  8 in total

1.  Double plating of intra-articular multifragmentary C3-type distal femoral fractures through the anterior approach.

Authors:  Mohamed A Imam; Ahmed Torieh; Ahmed Matthana
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-07-14

2.  [Advantages and disadvantages of locked plating].

Authors:  M Wagner
Journal:  Orthopade       Date:  2010-02       Impact factor: 1.087

Review 3.  [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

Authors:  M J Raschke; R Stange; C Kösters
Journal:  Unfallchirurg       Date:  2012-11       Impact factor: 1.000

Review 4.  [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

Authors:  M J Raschke; R Stange; C Kösters
Journal:  Chirurg       Date:  2012-08       Impact factor: 0.955

5.  Retrograde femoral nailing in elderly patients with supracondylar fracture femur; is it the answer for a clinical problem?

Authors:  Sameh El-Kawy; Sameh Ansara; Alaa Moftah; Hisham Shalaby; Vinod Varughese
Journal:  Int Orthop       Date:  2006-05-09       Impact factor: 3.075

6.  The effect of surgeon-controlled variables on construct stiffness in lateral locked plating of distal femoral fractures.

Authors:  Michael J Weaver; George W Chaus; Aidin Masoudi; Kaveh Momenzadeh; Amin Mohamadi; Edward K Rodriguez; Mark S Vrahas; Ara Nazarian
Journal:  BMC Musculoskelet Disord       Date:  2021-06-04       Impact factor: 2.362

7.  Results of the femur fractures treated with the new selfdynamisable internal fixator (SIF).

Authors:  Milorad Mitkovic; S Milenkovic; I Micic; D Mladenovic; Milan Mitkovic
Journal:  Eur J Trauma Emerg Surg       Date:  2011-10-28       Impact factor: 3.693

8.  Biomechanical Property of a Newly Designed Assembly Locking Compression Plate: Three-Dimensional Finite Element Analysis.

Authors:  Jiang-Jun Zhou; Min Zhao; Da Liu; Hai-Ying Liu; Cheng-Fei Du
Journal:  J Healthc Eng       Date:  2017-06-18       Impact factor: 2.682

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.