Literature DB >> 12805092

Dynamic synchronization analysis of venous pressure-driven cardiac output in rainbow trout.

Adrienne Robyn Minerick1, Hsueh-Chia Chang, Todd M Hoagland, Kenneth R Olson.   

Abstract

Measurement of venous function in vivo is inherently difficult. In this study, we used the Hilbert transform to examine the dynamic relationships between venous pressure and cardiac output (CO) in rainbow trout whose blood volume was continuously increased and decreased by ramp infusion and withdrawal (I/W). The dorsal aorta and ductus Cuvier were cannulated percutaneously and connected to pressure transducers; a flow probe was placed around the ventral aorta. Whole blood from a donor was then I/W via the dorsal aortic cannula at a rate of 10% of the estimated blood volume per minute, and the duration of I/W was varied from 40, 60, 80, 90, 120, 230, 240, 260, 300, and 340 s. Compliance [change in (delta) blood vol/deltavenous pressure] was 2.8 +/- 0.2 ml x mmHg-1x g-1 (N = 25 measurements; 6 fish with closed pericardium) and 2.8 +/- 0.3 ml. mmHg-1x kg-1 (N = 19 measurements, 4 fish with open pericardium). Compliance was positively correlated with the duration of I/W, indicative of cardiovascular reflex responses at longer I/W durations. In trout with closed pericardium, CO followed venous pressure oscillations with an average time lag of 4.2 +/- 1.0 s (N = 9); heart rate (HR) was inversely correlated with CO. These studies show that CO is entrained by modulation of venous pressure, not by HR. Thus, although trout have a rigid pericardium, venous pressure (vis-a-tergo), not cardiac suction (vis-a-fronte), appears to be the primary determinant of CO. Estimation of venous compliance by ramp-modulation of venous pressure is faster and less traumatic than classical capacitance measurements and appears applicable to a variety of vertebrate species, as does the Hilbert transform, which permits analysis of signals with disparate frequencies.

Entities:  

Mesh:

Year:  2003        PMID: 12805092     DOI: 10.1152/ajpregu.00228.2003

Source DB:  PubMed          Journal:  Am J Physiol Regul Integr Comp Physiol        ISSN: 0363-6119            Impact factor:   3.619


  3 in total

1.  Effects of salinity manipulations on blood pressures in an osmoconforming chordate, the hagfish, Eptatretus cirrhatus.

Authors:  J M Foster; M E Forster
Journal:  J Comp Physiol B       Date:  2006-07-26       Impact factor: 2.200

2.  Enforced exercise, but not acute temperature elevation, decreases venous capacitance in the stenothermal Antarctic fish Pagothenia borchgrevinki.

Authors:  Erik Sandblom; Michael Axelsson; William Davison
Journal:  J Comp Physiol B       Date:  2008-05-20       Impact factor: 2.200

3.  Circulatory function at sub-zero temperature: venous responses to catecholamines and angiotensin II in the Antarctic fish Pagothenia borchgrevinki.

Authors:  Erik Sandblom; Michael Axelsson; William Davison
Journal:  J Comp Physiol B       Date:  2008-10-22       Impact factor: 2.200

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.