Image reconstruction and the effect on dose calculation for hip prostheses.

Paul J Keall1, Leah B Chock, Robert Jeraj, Jeffrey V Siebers, Radhe Mohan.   

Abstract

High atomic number inserts, such as hip prostheses and dental fillings, cause streak artifacts on computed tomography (CT) images when filtered back-projection (FBP) methods are used. These streak artifacts severely degrade our ability to differentiate the tumor volume. Also, incorrect Hounsfield numbers yield incorrect electron density information that may lead to erroneous dose calculations, and, as a result, compromise clinical outcomes. The aim of this research was to evaluate the dosimetric consequences of artifacts during radiotherapy planning of a prostate patient containing a hip prosthesis. The CT numbers corresponding to an iron prosthesis were inserted into the right femoral head of an existing CT image set. This artifact-free image was used as the standard image set. CT projections through the image set formed the sinogram, from which filtered back projection and iterative deblurring methods were used to create reconstructed image sets. These reconstructed image sets contained artifacts. Prostate treatment plans were then calculated using a Monte Carlo system for the standard and reconstructed CT image sets. Close to the prosthesis, the CT numbers between the reconstructed and standard image sets differed substantially. However, because the CT number differences covered only a small area, the dose distributions on the reconstructed and standard image sets were not significantly different. The dose-volume histograms for the prostate, rectum, and bladder were virtually identical. Our results indicate that even though CT image artifacts restrict our ability to differentiate tumors and critical structures, the dose distributions for a prostate plan containing a hip prosthesis, calculated on both artifact-free image sets and image sets containing artifacts, are not significantly different.

Entities:  

Mesh:

Year:  2003        PMID: 12804710     DOI: 10.1016/S0958-3947(02)00246-7

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  3 in total

Review 1.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar

2.  Effects of 16-bit CT imaging scanning conditions for metal implants on radiotherapy dose distribution.

Authors:  Liugang Gao; Hongfei Sun; Xinye Ni; Mingming Fang; Tao Lin
Journal:  Oncol Lett       Date:  2017-12-11       Impact factor: 2.967

3.  Impact of the Tiloop Bra® mesh in CT images and dose delivery in breast radiotherapy.

Authors:  Cristina Camacho; M Carmen Pujades; Jose Perez-Calatayud; Françoise Lliso; Vicente Carmona; Alejandro Tormo; Facundo Ballester
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.