Literature DB >> 12801682

Optimisation of sample preparation methods for air imaging of ocular mucins by AFM.

Debra J Brayshaw1, Monica Berry, Terence J McMaster.   

Abstract

The addition of cations to the imaging buffer for AFM has been previously shown to improve the binding of biological molecules to mica. Investigations were carried out to find the concentration of NiCl(2) required to immobilize mucin molecules on a freshly cleaved mica surface, for imaging using intermittent contact in air. Drop-deposition of samples prepared in HEPES buffer with 1, 2 and 5mM NiCl(2) revealed the sensitivity of the mucin molecules to salt. Dialysis of the mucin solutions dramatically reduced the amount of salt present and allowed single molecules to be imaged, revealing a variation in thickness along their length. Spray deposition of the same mucin solutions produced single molecules that, although less affected by co-adsorbed salt, showed a degree of self-folding. This shows the sensitive balance between HEPES and NiCl(2) required for successful imaging of the sub-molecular features of individual mucin molecules.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12801682     DOI: 10.1016/S0304-3991(03)00054-8

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  5 in total

Review 1.  The applications of atomic force microscopy to vision science.

Authors:  Julie A Last; Paul Russell; Paul F Nealey; Christopher J Murphy
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-12       Impact factor: 4.799

2.  Modified Protein Misfolding Cyclic Amplification Overcomes Real-Time Quaking-Induced Conversion Assay Inhibitors in Deer Saliva To Detect Chronic Wasting Disease Prions.

Authors:  Kristen A Davenport; Clare E Hoover; Nathaniel D Denkers; Candace K Mathiason; Edward A Hoover
Journal:  J Clin Microbiol       Date:  2018-08-27       Impact factor: 5.948

3.  Pharmaceutical nanoparticles and the mucin biopolymer barrier.

Authors:  Ghaith Aljayyoussi; Muthanna Abdulkarim; Peter Griffiths; Mark Gumbleton
Journal:  Bioimpacts       Date:  2012-11-22

4.  Dynamic molecular resolution imaging of preocular fluid impressions.

Authors:  M Berry; D Brayshaw; T J McMaster
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

5.  Gloss phenomena and image analysis of atomic force microscopy in molecular and cell biology.

Authors:  Jie Zhu; Tanya Sabharwal; Lianhong Guo; Aruna Kalyanasundaram; Guodong Wang
Journal:  Scanning       Date:  2009 Mar-Apr       Impact factor: 1.932

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.