Literature DB >> 12798989

Examination of normalized pulse volume-blood volume relationship: toward a more valid estimation of the finger sympathetic tone.

Gohichi Tanaka1, Yukihiro Sawada.   

Abstract

The pulsatile ac component (DeltaI) superimposed on the transmitted dc components (I: tissue plus blood) are obtained from a near-infrared finger photoplethysmogram using a wavelength of 810 nm. Only the dc component is given in an ischaemic circulatory state (I(t): tissue only). Based on Lambert-Beer's law, normalized pulse volume (NPV; =DeltaI/I) and blood volume [BV; =ln(I(t)/I)] have recently been advocated as quantitative measures. In this study, the NPV-BV relationship was examined using the finger occlusion method during rest and mental arithmetic in 16 female undergraduates. Finger vascular tone during stress was evaluated by the distance of the linear and parallel NPV-BV regression lines (D(NB)) between rest and stress conditions. A reference standard was provided by the linear regression lines of compliance index (CI=NPV/pulse pressure) and BV to the transmural pressure. The estimates at 40 mmHg of transmural pressure, as an arbitrarily chosen reference point, were calculated (CI40 and BV40). D(NB) correlated well with them (r=0.81 and 0.94, respectively). The multiple regression with mean blood pressure indicated that the combination of D(NB) and the reactivities in heart period could explain approximately 50% of valiance in pressor response. In conclusion, D(NB) is easily obtainable from the NPV-BV function and seems to be more specific and valid than NPV as an index of finger sympathetic tone, since it adjusts the mechanical effect of arterial distending pressure.

Mesh:

Year:  2003        PMID: 12798989     DOI: 10.1016/s0167-8760(03)00056-4

Source DB:  PubMed          Journal:  Int J Psychophysiol        ISSN: 0167-8760            Impact factor:   2.997


  4 in total

Review 1.  Mitigation of stress: new treatment alternatives.

Authors:  Ahmad Rauf Subhani; Nidal Kamel; Mohamad Naufal Mohamad Saad; Nanda Nandagopal; Kenneth Kang; Aamir Saeed Malik
Journal:  Cogn Neurodyn       Date:  2017-11-29       Impact factor: 5.082

2.  iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

Authors:  Kenta Matsumura; Peter Rolfe; Jihyoung Lee; Takehiro Yamakoshi
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

3.  Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation.

Authors:  Xiaorong Ding; Bryan P Yan; Yuan-Ting Zhang; Jing Liu; Ni Zhao; Hon Ki Tsang
Journal:  Sci Rep       Date:  2017-09-14       Impact factor: 4.379

4.  Validity of Smartphone Heart Rate Variability Pre- and Post-Resistance Exercise.

Authors:  Clifton J Holmes; Michael V Fedewa; Lee J Winchester; Hayley V MacDonald; Stefanie A Wind; Michael R Esco
Journal:  Sensors (Basel)       Date:  2020-10-09       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.