Jinghua Li1, Yingguang Shao, Zhaoan Chen, Runzi Cong, Junde Wang, Xueliang Liu.
Abstract
The suitability of membrane cartridges for the removal of endotoxin from both distilled water and interferon preparations was examined. The endotoxin concentrations were reduced to 4.0 and 7.3 EU/ml, respectively, when about 4000 ml of distilled water with 20 and 28 EU/ml were passed through the deoxycholate and chitosan immobilized membrane cartridges. When 200 ml of interferon preparation with endotoxin concentration more than 80 EU/ml and pH 3.9 were applied to a deoxycholate immobilized membrane cartridge at a flow-rate of 9 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. However, if an interferon preparation of 450 ml, with more than 80 EU/ml of endotoxin and pH 3.9 was applied to the chitosan immobilized membrane cartridge at a flow-rate of 18 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml.Entities: