Literature DB >> 12798160

Kinetic differentiation mode chromatography using 8-quinolinol and fluorimetric detection for sensitive determination of aluminum adhering to the gastric mucosa.

Koji Kashimura1, Yasuhiro Mizushima, Eiichi Hoshino, Shuzo Matsubara.   

Abstract

A highly sensitive method of kinetic differentiation (KD) mode high-performance liquid chromatography (HPLC) with fluorimetric detection was established using 8-quinolinol to measure aluminum adhering to the gastric mucosa. After sucralfate was hydrolyzed by 1 mol/l hydrochloric acid, an 8-quinolinolate-aluminum complex was produced by reacting aluminum with an 8-quinolinol solution. Then contaminants in the gastric mucosa and sucralfate were removed by liquid-liquid extraction with chloroform. Next, the 8-quinolinolate-aluminum complex was separated on a reversed-phase column that was specifically designed to detect aluminum (50 x 4.6-mm I.D.). Separation was done at a flow-rate of 0.8 ml/min, using BES buffer containing sodium dodecyl sulfate (pH 7.0) as the mobile phase. Fluorescence was detected at 370 nm (excitation) and 504 nm (emission). The sensitivity of this method was more than 1000 times greater than that of absorptiometry using 8-quinolinol. The detection and quantitation limits were 1.68 and 5.11 ng/ml, respectively. When tested with aluminum solutions of 10, 30, and 90 ng/ml, the intra-assay and inter-assay coefficients of variation were below 7.1%, with an error of less than 8.3%. Aluminum adhering to the gastric mucosa was determined by HPLC and absorptiometry after administration of sucralfate to rats. The HPLC method showed that aluminum levels were higher at sites of ulceration than in the normal mucosa at all times after sucralfate administration. When the values above zero obtained for absorptiometry were assessed, there was a significant correlation (r=0.993, P<0.0001) between the aluminum concentrations measured by the two methods. This new HPLC method could be applied to the determination of aluminum in small samples, such as human gastric mucosal biopsy specimens.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12798160     DOI: 10.1016/s1570-0232(03)00159-4

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Identification of the Al-binding proteins that account for aluminum neurotoxicity and transport in vivo.

Authors:  Dai Cheng; Xiaomei Wang; Yu Xi; Jiankang Cao; Weibo Jiang
Journal:  Toxicol Res (Camb)       Date:  2017-12-01       Impact factor: 3.524

2.  Effect of sucralfate on antibiotic therapy for Helicobacter pylori infection in mice.

Authors:  Koichiro Watanabe; Kazunari Murakami; Ryugo Sato; Koji Kashimura; Masahiro Miura; Satoshi Ootsu; Hajime Miyajima; Masaru Nasu; Tadayoshi Okimoto; Masaaki Kodama; Toshio Fujioka
Journal:  Antimicrob Agents Chemother       Date:  2004-12       Impact factor: 5.191

3.  Pre-Column Derivatization HPLC Procedure for the Quantitation of Aluminium Chlorohydrate in Antiperspirant Creams Using Quercetin as Chromogenic Reagent.

Authors:  Eleni Kalogria; Athanasia Varvaresou; Spyridon Papageorgiou; Evaggelia Protopapa; Ioannis Tsaknis; Alexios Matikas; Irene Panderi
Journal:  Chromatographia       Date:  2014-07-10       Impact factor: 2.044

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.