Literature DB >> 12796131

Detection of TIMI-3 flow before mechanical reperfusion with ultrasonic tissue characterization in patients with anterior wall acute myocardial infarction.

Katsuomi Iwakura1, Hiroshi Ito, Shigeo Kawano, Atsushi Okamura, Katsuaki Asano, Tadashi Kuroda, Koji Tanaka, Tohru Masuyama, Masatsugu Hori, Kenshi Fujii.   

Abstract

BACKGROUND: Spontaneous coronary reperfusion with TIMI-3 flow is associated with favorable clinical outcomes in patients with acute myocardial infarction (AMI). We investigated the ability of analyzing cardiac cycle-dependent variation of myocardial integrated backscatter (IBS) for predicting spontaneous reperfusion in anterior AMI. METHODS AND
RESULTS: We recorded IBS images on admission in 104 patients with first anterior wall AMI and subsequently performed coronary angiography and coronary intervention. We measured the cyclic variation of IBS within the infarct zone and expressed its magnitude as phase-corrected magnitude (PCM) by giving positive and negative values when it showed synchronous and asynchronous contraction, respectively. Twenty-three patients showing TIMI-3 flow at the initial coronary angiography had smaller peak creatine kinase value than 57 patients with initial TIMI-0/1 flow (864+/-961 versus 2358+/-1757 IU/L; P=0.0002) and better percent wall thickening within risk area (36.1+/-15.1%) than those with TIMI-2 (16.7+/-12.8%, P<0.0001) or TIMI-0/1 (5.1+/-11.6, P<0.0001). The patients with initial TIMI-3 had higher PCM (2.7+/-1.3 dB) than those with TIMI-2 (-0.3+/-2.2 dB, P<0.0001) or those with TIMI-0/1 (-1.1+/-2.4 dB, P<0.0001). Using PCM=1.0 dB as the cutoff point, PCM detected TIMI-3 flow with 95.7% sensitivity and 90.1% specificity. Multivariable logistic regression analysis revealed that only PCM is an independent predictor for spontaneous reperfusion among the hemodynamic, echocardiographic, and electrocardiographic variables.
CONCLUSIONS: Analysis of myocardial IBS could detect spontaneous reperfusion noninvasively in the emergent stage of anterior AMI.

Entities:  

Mesh:

Year:  2003        PMID: 12796131     DOI: 10.1161/01.CIR.0000074228.53741.72

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  The diastolic function to cyclic variation of myocardial ultrasonic backscatter relation: the influence of parameterized diastolic filling (PDF) formalism determined chamber properties.

Authors:  Christopher W Lloyd; Leonid Shmuylovich; Mark R Holland; James G Miller; Sándor J Kovács
Journal:  Ultrasound Med Biol       Date:  2011-06-16       Impact factor: 2.998

2.  Usefulness of peak systolic strain measurement by automated function imaging in the prediction of coronary perfusion in patients with acute myocardial infarction.

Authors:  Jung Sun Cho; Kye Hun Kim; Woo Seok Lee; Hyun Ju Yoon; Nam Sik Yoon; Young Joon Hong; Hyung Wook Park; Ju Han Kim; Youngkeun Ahn; Myung Ho Jeong; Jeong Gwan Cho; Jong Chun Park; Jung Chaee Kang
Journal:  Korean J Intern Med       Date:  2010-08-31       Impact factor: 2.884

3.  The Impact of Lesion Complexity and the CHA2DS2-VASc Score on Spontaneous Reperfusion in Patients with ST-Segment Elevation Myocardial Infarction.

Authors:  Gökhan Alıcı; Hasan Ali Barman; Adem Atıcı; Sevil Tuğrul; Ömer Genç; İrfan Şahin
Journal:  Int J Clin Pract       Date:  2022-02-09       Impact factor: 3.149

4.  Quantitative analysis of the magnitude and time delay of cyclic variation of myocardial backscatter from asymptomatic type 2 diabetes mellitus subjects.

Authors:  Allyson A Gibson; Jean E Schaffer; Linda R Peterson; Kyle R Bilhorn; Karla M Robert; Troy A Haider; Marsha S Farmer; Mark R Holland; James G Miller
Journal:  Ultrasound Med Biol       Date:  2009-07-17       Impact factor: 2.998

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.