Degradation of hydroxyapatite coating on a well-functioning femoral component.

N Aebli1, J Krebs, D Schwenke, H Stich, P Schawalder, J C Theis.   

Abstract

We carried out a histological study of a proximally hydroxyapatite (HA)-coated femoral component, retrieved after 9.5 years of good function. The HA coating had completely degraded. Bone was in direct contact with the titanium surface in all the areas which had been coated, with no interposing fibrous tissue. There were no signs of particles, third-body wear, adverse tissue reactions or osteolysis. Bone remodelling was evident by the presence of resorption lacunae; tetracycline labelling showed bone laid down six years after implantation. The loss of the HA-coating had no negative effect on the osseo-integration of the stem. We conclude that the HA coating contributes to the fixation of the implant and that its degradation does not adversely affect the long-term fixation.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12793552     DOI: 10.1302/0301-620x.85b4.13605

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Preparation and analysis of chemically gradient functional bioceramic coating formed by pulsed laser deposition.

Authors:  P Rajesh; C V Muraleedharan; S Sureshbabu; Manoj Komath; Harikrishna Varma
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

2.  Osteoblast Attachment on Titanium Coated with Hydroxyapatite by Atomic Layer Deposition.

Authors:  Elina Kylmäoja; Jani Holopainen; Faleh Abushahba; Mikko Ritala; Juha Tuukkanen
Journal:  Biomolecules       Date:  2022-04-29

3.  Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses.

Authors:  Alphons J Tonino; Bart C H van der Wal; Ide C Heyligers; Bernd Grimm
Journal:  Clin Orthop Relat Res       Date:  2008-10-15       Impact factor: 4.176

4.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

5.  Survival and performance of a dual tapered-wedge fully HA-coated press fit femoral stem.

Authors:  Ramakanth R Yakkanti; Dylan N Greif; Dennis J Vanden Berge; Raymond P Robinson
Journal:  Arch Orthop Trauma Surg       Date:  2022-03-03       Impact factor: 3.067

  5 in total