Literature DB >> 12790811

Evaluation of personal, environmental and biological exposure of paediatric anaesthetists to nitrous oxide and sevoflurane.

N Raj1, K A Henderson, J E Hall, I M Aguilera, M Harmer, A Hutchings, B Williams.   

Abstract

Paediatric anaesthetists are at higher risk of exposure to waste anaesthetic gases, which often exceed set safety limits. Recommended personal diffusive sampling techniques for monitoring exposure to waste anaesthetic gases may not give a true profile of exposure and hence biological sampling may also be necessary. We evaluated the exposure of paediatric anaesthetists to nitrous oxide and sevoflurane as assessed by personal environmental and biological samples. The influence of venue and technique, and the strength of the relationship among the various sampling techniques were analysed. The study found that exposure to nitrous oxide during paediatric anaesthetic inductions is still a major problem, although exposure to sevoflurane was usually within the accepted limits. The type of breathing system used and the presence of scavenging seem to influence this exposure, though surprisingly, the induction technique or the methods of airway control do not. No significant relationship was found between the various biological indicators measured.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12790811     DOI: 10.1046/j.1365-2044.2003.03235.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Effect of volatile anesthetics on oxidative stress due to occupational exposure.

Authors:  Hülya Türkan; Ahmet Aydin; Ahmet Sayal
Journal:  World J Surg       Date:  2005-04       Impact factor: 3.352

2.  Environmental and biological measurements of isoflurane and sevoflurane in operating room personnel.

Authors:  Abbas Jafari; Rogaieh Bargeshadi; Fatemeh Jafari; Iraj Mohebbi; Mohammad Hajaghazadeh
Journal:  Int Arch Occup Environ Health       Date:  2017-12-15       Impact factor: 3.015

Review 3.  Anaesthetic management of a known or suspected malignant hyperthermia susceptible patient.

Authors:  P K Gupta; J G Bilmen; P M Hopkins
Journal:  BJA Educ       Date:  2021-02-19

4.  Evaluation of Bio-VOC Sampler for Analysis of Volatile Organic Compounds in Exhaled Breath.

Authors:  Jae Kwak; Maomian Fan; Sean W Harshman; Catherine E Garrison; Victoria L Dershem; Jeffrey B Phillips; Claude C Grigsby; Darrin K Ott
Journal:  Metabolites       Date:  2014-09-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.