Literature DB >> 12790475

Fiber Fabry-Perot sensors for detection of partial discharges in power transformers.

Bing Yu1, Dae Woong Kim, Jiangdong Deng, Hai Xiao, Anbo Wang.   

Abstract

A diaphragm-based interferometric fiberoptic sensor that uses a low-coherence light source was designed and tested for on-line detection of the acoustic waves generated by partial discharges inside high-voltage power transformers. The sensor uses a fused-silica diaphragm and a single-mode optical fiber encapsulated in a fused-silica glass tube to form an extrinsic Fabry-Perot interferometer, which is interrogated by low-coherence light. Test results indicate that these fiber optic acoustic sensors are capable of faithfully detecting acoustic signals propagating inside transformer oil with high sensitivity and wide bandwidth.

Entities:  

Year:  2003        PMID: 12790475     DOI: 10.1364/ao.42.003241

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  15 in total

1.  Diffuse reflectance spectroscopy of epithelial tissue with a smart fiber-optic probe.

Authors:  Bing Yu; Amy Shah; Vivek K Nagarajan; Daron G Ferris
Journal:  Biomed Opt Express       Date:  2014-02-10       Impact factor: 3.732

2.  Sensitivity and phase response of FBG based acousto-optic sensors for real-time MRI applications.

Authors:  Yusuf Samet Yaras; Dursun Korel Yildirim; Ozgur Kocaturk; F Levent Degertekin
Journal:  OSA Contin       Date:  2020-03-15

3.  Ultra-High SNR Demodulation Method for Optical Fiber Sensors Applied in Power Transformer Partial Discharge Detection.

Authors:  Jixian Qiao; Weichao Zhang; Yanqi Wang; Qibing Shao; Jianlong Cai; Hong Zhao
Journal:  Sensors (Basel)       Date:  2022-04-07       Impact factor: 3.847

4.  Fiber loop ringdown - a time-domain sensing technique for multi-function fiber optic sensor platforms: current status and design perspectives.

Authors:  Chuji Wang
Journal:  Sensors (Basel)       Date:  2009-09-28       Impact factor: 3.576

5.  Fiber optic sensor for acoustic detection of partial discharges in oil-paper insulated electrical systems.

Authors:  Julio Posada-Roman; Jose A Garcia-Souto; Jesus Rubio-Serrano
Journal:  Sensors (Basel)       Date:  2012-04-12       Impact factor: 3.576

6.  A Novel High-Performance Beam-Supported Membrane Structure with Enhanced Design Flexibility for Partial Discharge Detection.

Authors:  Chenzhao Fu; Wenrong Si; Haoyong Li; Delin Li; Peng Yuan; Yiting Yu
Journal:  Sensors (Basel)       Date:  2017-03-15       Impact factor: 3.576

7.  Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System.

Authors:  Yu Wang; Xiaomin Li; Yan Gao; Hongjuan Zhang; Dong Wang; Baoquan Jin
Journal:  Sensors (Basel)       Date:  2018-05-04       Impact factor: 3.576

Review 8.  Structural Health Monitoring Using Fibre Optic Acoustic Emission Sensors.

Authors:  James Owen Willberry; Mayorkinos Papaelias
Journal:  Sensors (Basel)       Date:  2020-11-08       Impact factor: 3.576

9.  Experimental Strain Measurement Approach Using Fiber Bragg Grating Sensors for Monitoring of Railway Switches and Crossings.

Authors:  Abdelfateh Kerrouche; Taoufik Najeh; Pablo Jaen-Sola
Journal:  Sensors (Basel)       Date:  2021-05-24       Impact factor: 3.576

10.  Laser-machined microcavities for simultaneous measurement of high-temperature and high-pressure.

Authors:  Zengling Ran; Shan Liu; Qin Liu; Ya Huang; Haihong Bao; Yanjun Wang; Shucheng Luo; Huiqin Yang; Yunjiang Rao
Journal:  Sensors (Basel)       Date:  2014-08-07       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.