Literature DB >> 12790301

Ions released from dental amalgams in contact with titanium.

Shi-Duk Lim1, Yukyo Takada, Kyo-Han Kim, Osamu Okuno.   

Abstract

The ions released from conventional and high-copper amalgams in contact with titanium were quantitatively analyzed in a 0.9% NaCl solution at 37 degrees C when the surface area ratio of titanium/amalgam was set up as 1/10, 1/1, or 10/1. The corrosion potentials of the amalgams and titanium were measured under the same conditions. Surface analyses on the amalgams were also employed using SEM with WDS. Though the potential of the conventional amalgam was always lower than that of titanium, that of the high-copper amalgam was reversed during the early stage of immersion and remained lower. When the surface area ratio of titanium grew at 10/1, tin and copper ions released from the conventional and high-copper amalgam, respectively, increased significantly compared with those of each amalgam that was not in contact with titanium. The galvanic corrosion in such a large surface area of titanium possibly led to the heavy corrosion of the amalgams.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12790301     DOI: 10.4012/dmj.22.96

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  4 in total

1.  Photoletter to the editor: Exfoliative cheilitis associated with titanium dental implants and mercury amalgam.

Authors:  Paolo D Pigatto; Emilio Berti; Francesco Spadari; Gian Paolo Bombeccari; Gianpaolo Guzzi
Journal:  J Dermatol Case Rep       Date:  2011-12-12

2.  Elevated Systemic L-Kynurenine/L-Tryptophan Ratio and Increased IL-1 Beta and Chemokine (CX3CL1, MCP-1) Proinflammatory Mediators in Patients with Long-Term Titanium Dental Implants.

Authors:  José Joaquín Merino; María Eugenia Cabaña-Muñoz; Adolfo Toledano Gasca; Alba Garcimartín; Juana Benedí; Fabio Camacho-Alonso; José María Parmigiani-Izquierdo
Journal:  J Clin Med       Date:  2019-09-02       Impact factor: 4.241

3.  Effect of Self-etch Adhesives on Self-sealing Ability of High-Copper Amalgams.

Authors:  Saied Mostafa Moazzami; Horieh Moosavi; Maryam Moddaber; Reza Parvizi; Mohamad Hadi Moayed; Nima Mokhber; Michael Meharry; Reza B Kazemi
Journal:  J Dent (Shiraz)       Date:  2016-12

4.  Increased Systemic Malondialdehyde Levels and Decreased Mo/Co, Co/Fe2+ Ratios in Patients with Long-Term Dental Titanium Implants and Amalgams.

Authors:  María Eugenia Cabaña-Muñoz; José María Parmigiani-Izquierdo; Fabio Camacho Alonso; José Joaquín Merino
Journal:  J Clin Med       Date:  2019-01-12       Impact factor: 4.241

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.