Literature DB >> 12788554

A handheld real time thermal cycler for bacterial pathogen detection.

James A Higgins1, Shanavaz Nasarabadi, Jeffrey S Karns, Daniel R Shelton, Mary Cooper, Aiah Gbakima, Ronald P Koopman.   

Abstract

The handheld advanced nucleic acid analyzer (HANAA) is a portable real time thermal cycler unit that weighs under 1 kg and uses silicon and platinum-based thermalcycler units to conduct rapid heating and cooling of plastic reaction tubes. Two light emitting diodes (LED) provide greater than 1 mW of electrical power at wavelengths of 490 nm (blue) and 525 nm (green), allowing detection of the dyes FAM and JOE/TAMRA. Results are displayed in real time as bar graphs, and up to three, 4-sample assays can be run on the charge of the 12 V portable battery pack. The HANAA was evaluated for detection of defined Escherichia coli strains, and wild-type colonies isolated from stream water, using PCR for the lac Z and Tir genes. PCR reactions using SYBR Green dye allowed detection of E. coli ATCC 11775 and E. coli O157:H7 cells in under 30 min of assay time; however, background fluorescence associated with dye binding to nonspecific PCR products was present. DNA extracted from three isolates of Bacillus anthracis Ames, linked to a bioterrorism incident in Washington DC in October 2001, were also successfully tested on the HANAA using primers for the vrrA and capA genes. Positive results were observed at 32 and 22 min of assay time, respectively. A TaqMan probe specific to the aroQ gene of Erwinia herbicola was tested on the HANAA and when 500 cells were used as template, positive results were observed after only 7 min of assay time. Background fluorescence associated with the use of the probe was negligible. The HANAA is unique in offering real time PCR in a handheld format suitable for field use; a commercial version of the instrument, offering six reaction chambers, is available as of Fall 2002.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12788554     DOI: 10.1016/s0956-5663(02)00252-x

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

Review 1.  Sample pretreatment and nucleic acid-based detection for fast diagnosis utilizing microfluidic systems.

Authors:  Jung-Hao Wang; Chih-Hung Wang; Gwo-Bin Lee
Journal:  Ann Biomed Eng       Date:  2011-12-07       Impact factor: 3.934

Review 2.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

3.  Detection of water-borne E. coli O157 using the integrating waveguide biosensor.

Authors:  Peixuan Zhu; Daniel R Shelton; Jeffrey S Karns; Appavu Sundaram; Shuhong Li; Pete Amstutz; Cha-Mei Tang
Journal:  Biosens Bioelectron       Date:  2005-10-15       Impact factor: 10.618

4.  An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids.

Authors:  Dafeng Chen; Michael Mauk; Xianbo Qiu; Changchun Liu; Jitae Kim; Sudhir Ramprasad; Serge Ongagna; William R Abrams; Daniel Malamud; Paul L A M Corstjens; Haim H Bau
Journal:  Biomed Microdevices       Date:  2010-08       Impact factor: 2.838

5.  Development of quantitative real-time PCR assays for detection and quantification of surrogate biological warfare agents in building debris and leachate.

Authors:  Pascal E Saikaly; Morton A Barlaz; Francis L de Los Reyes
Journal:  Appl Environ Microbiol       Date:  2007-08-24       Impact factor: 4.792

6.  Rapid DNA amplification using a battery-powered thin-film resistive thermocycler.

Authors:  Keith E Herold; Nikolay Sergeev; Andriy Matviyenko; Avraham Rasooly
Journal:  Methods Mol Biol       Date:  2009

Review 7.  Absorbance Based Light Emitting Diode Optical Sensors and Sensing Devices.

Authors:  Martina O'Toole; Dermot Diamond
Journal:  Sensors (Basel)       Date:  2008-04-07       Impact factor: 3.576

8.  Nucleic Acid-based Detection of Bacterial Pathogens Using Integrated Microfluidic Platform Systems.

Authors:  Clarissa Lui; Nathaniel C Cady; Carl A Batt
Journal:  Sensors (Basel)       Date:  2009-05-18       Impact factor: 3.576

9.  The rotary zone thermal cycler: a low-power system enabling automated rapid PCR.

Authors:  Michael S Bartsch; Harrison S Edwards; Daniel Lee; Caroline E Moseley; Karen E Tew; Ronald F Renzi; James L Van de Vreugde; Hanyoup Kim; Daniel L Knight; Anupama Sinha; Steven S Branda; Kamlesh D Patel
Journal:  PLoS One       Date:  2015-03-31       Impact factor: 3.240

10.  Cationized Magnetoferritin Enables Rapid Labeling and Concentration of Gram-Positive and Gram-Negative Bacteria in Magnetic Cell Separation Columns.

Authors:  S Correia Carreira; J Spencer; W Schwarzacher; A M Seddon
Journal:  Appl Environ Microbiol       Date:  2016-05-31       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.