Literature DB >> 12788122

The Ahmed drainage implant in the treatment of pediatric glaucoma.

Yair Morad1, Craig E Donaldson, Yuri M Kim, Mohamed Abdolell, Alex V Levin.   

Abstract

PURPOSE: To report the safety and efficacy of Ahmed Glaucoma Valve (New World Medical, Inc., Rancho Cucamonga, California, USA) implantation for the management of pediatric glaucoma in the early and intermediate follow-up period.
DESIGN: Consecutive interventional case series.
METHOD: A retrospective chart review was conducted on 60 eyes (44 patients, age range at surgery 1.5 months to 16 years, average 6 +/- 4.9 years), with pediatric glaucoma that underwent Ahmed Glaucoma Valve implantation for medically uncontrolled intraocular pressure (IOP) between the years 1995 and 2000. Outcome measures were control of IOP below 21 mm Hg, the need for antiglaucoma medications after surgery, and loss of 2 or more lines of Snellen acuity. Complications were monitored.
RESULTS: The postoperative follow-up period for each eye averaged 24.3 +/- 16 months (range, 3 to 60 months). At last follow-up, IOP was controlled in 44 eyes (73%), 11 of which did not need antiglaucoma therapy. Kaplan-Meier life-table analysis showed probability of success with or without medications of 93% (95% confidence interval [CI], 86%-100%), 86% (95% CI, 77%-96%), 71% (95% CI, 59%-87%), and 45% (95% CI, 28%-80%) after 12, 24, 36, and 48 months of follow-up. Average IOP decreased from 32.8 +/- 6.2 before surgery to 16.6 +/- 8.0 postoperatively (P <.0001). The average number of medications used decreased from 4.4 +/- 1.97 to 2.0 +/- 2.0 (P <.0001). Kaplan-Meier survival analysis did not reveal any difference in survival profiles related to specific diagnosis of glaucoma, age (above or below 18 months), or prior surgery. Complications occurred in 30 eyes (50%). Although most resolved or were treated successfully, four patients had severe visual loss during the follow-up. Uveitis was a significant risk factor for tube exposure (Fisher exact test, P =.006).
CONCLUSIONS: Ahmed Glaucoma Valve implantation is an effective treatment for pediatric glaucoma, although patients frequently require antiglaucoma medications. However, a high rate of potentially sight-threatening postoperative complications warrants ongoing close follow-up.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12788122     DOI: 10.1016/s0002-9394(02)02274-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  33 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  D S Minckler; S S Vedula; T J Li; M C Mathew; R S Ayyala; B A Francis
Journal:  Cochrane Database Syst Rev       Date:  2006-04-19

2.  Ahmed valve drainage implant surgery in the management of paediatric aphakic glaucoma.

Authors:  C Kirwan; M O'Keefe; B Lanigan; U Mahmood
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

3.  Baerveldt glaucoma implant in paediatric patients.

Authors:  K A van Overdam; J T H N de Faber; H G Lemij; P W T de Waard
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

Review 4.  Endophthalmitis associated with the Ahmed glaucoma valve implant.

Authors:  A A Al-Torbak; S Al-Shahwan; I Al-Jadaan; A Al-Hommadi; D P Edward
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

5.  Clinical findings following Ahmed Glaucoma Valve implantation in pediatric glaucoma.

Authors:  Amir Pirouzian; Joseph L Demer
Journal:  Clin Ophthalmol       Date:  2008-03

6.  Ahmed glaucoma valve implant: experience in East Africa.

Authors:  D O Kiage; D Gradin; S Gichuhi; K F Damji
Journal:  Middle East Afr J Ophthalmol       Date:  2009-07

7.  Evaluation of Ahmed glaucoma valve implantation through a needle-generated scleral tunnel in Mexican children with glaucoma.

Authors:  Oscar Albis-Donado; Félix Gil-Carrasco; Rafael Romero-Quijada; Ravi Thomas
Journal:  Indian J Ophthalmol       Date:  2010 Sep-Oct       Impact factor: 1.848

8.  Transcorneal tube erosion of an ahmed valve implant in an adult.

Authors:  Sami Al-Shahwan
Journal:  Middle East Afr J Ophthalmol       Date:  2010-10

9.  Tenon advancement and duplication technique to prevent postoperative Ahmed valve tube exposure in patients with refractory glaucoma.

Authors:  Nevbahar Tamcelik; Ahmet Ozkok; Ahmet Murat Sarıcı; Eray Atalay; Huseyin Yetik; Kivanc Gungor
Journal:  Jpn J Ophthalmol       Date:  2013-05-24       Impact factor: 2.447

10.  Long term comparison between single stage Baerveldt and Ahmed glaucoma implants in pediatric glaucoma.

Authors:  Nehal M S El Gendy; Jonathan C Song
Journal:  Saudi J Ophthalmol       Date:  2012-07-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.