Literature DB >> 12784007

Accuracy of ultrasound imaging of the rotator cuff in shoulders that are painful postoperatively.

William D Prickett1, Sharlene A Teefey, Leesa M Galatz, Ryan P Calfee, William D Middleton, Ken Yamaguchi.   

Abstract

BACKGROUND: Evaluation of the rotator cuff in a shoulder that has been persistently painful postoperatively could be challenging. Magnetic resonance imaging has been the preferred imaging method, but accuracy rates have been lower for those shoulders than for shoulders that have not been operated on; also, magnetic resonance imaging is susceptible to suture anchor artifact. The purpose of this study was to evaluate the diagnostic accuracy of ultrasound for evaluating the rotator cuff in shoulders that are painful postoperatively.
METHODS: The records of forty-four consecutive patients who had undergone both a high-resolution ultrasound examination and subsequent shoulder arthroscopy were retrospectively reviewed. Thirty-four patients underwent rotator cuff repair at the time of the arthroscopy, and ten had subacromial decompression or another procedure without cuff repair. The results of the ultrasound examination were compared with the intraoperative findings of the arthroscopic examination (the "gold standard").
RESULTS: Ultrasound led to a correct diagnosis for forty of the forty-four patients. Twenty-two recurrent rotator cuff tears and twenty-two intact rotator cuffs were found at surgery. Ultrasound correctly identified twenty of the twenty-two rotator cuff tears (true-positive results) and twenty of the twenty-two intact rotator cuffs (true-negative results). Two intact cuffs were identified as having a full-thickness tear (false-positive results), and two cuffs with a full-thickness rotator cuff tear were identified as being intact (false-negative results). The sensitivity and specificity of ultrasound for identifying rotator cuff integrity postoperatively were 91% and 86%, respectively. The accuracy was 89%.
CONCLUSIONS: Ultrasound is a highly accurate imaging study for evaluating the integrity of the rotator cuff in shoulders that have undergone an operation. Its accuracy for operatively treated shoulders appears to be comparable with that previously reported for shoulders that had not been operated on.

Entities:  

Mesh:

Year:  2003        PMID: 12784007     DOI: 10.2106/00004623-200306000-00016

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  46 in total

1.  Subscapularis release in shoulder replacement determines structural muscular changes.

Authors:  Lieven Franciscus De Wilde; Tineke De Coninck; Francis De Neve; Bart M Berghs
Journal:  Clin Orthop Relat Res       Date:  2012-02-24       Impact factor: 4.176

Review 2.  Multimodality imaging of the postoperative shoulder.

Authors:  Klaus Woertler
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

3.  Proximal humeral migration in shoulders with symptomatic and asymptomatic rotator cuff tears.

Authors:  Jay D Keener; Anthony S Wei; H Mike Kim; Karen Steger-May; Ken Yamaguchi
Journal:  J Bone Joint Surg Am       Date:  2009-06       Impact factor: 5.284

4.  Cigarette smoking increases the risk for rotator cuff tears.

Authors:  Keith M Baumgarten; David Gerlach; Leesa M Galatz; Sharlene A Teefey; William D Middleton; Konstantinos Ditsios; Ken Yamaguchi
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

5.  Arthroscopic repair of large and massive rotator cuff tears using the biceps-incorporating technique: mid-term clinical and anatomical results.

Authors:  Jong-Hun Ji; Mohamed Shafi; Jae-Jung Jeong; Sang-Eun Park
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-10-02

Review 6.  [Significance of sonography in traumatology and orthopedics: part 1: ultrasonography of the musculoskeletal system].

Authors:  C Tesch; B Friemert; J Huhnholz; J V Wening
Journal:  Unfallchirurg       Date:  2008-09       Impact factor: 1.000

7.  Ultrasonic evaluation of the repair integrity can predict functional outcomes after arthroscopic double-row rotator cuff repair.

Authors:  Johannes Barth; Elias Fotiadis; Renaud Barthelemy; Sophie Genna; Mo Saffarini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-20       Impact factor: 4.342

Review 8.  What can be seen after rotator cuff repair: a brief review of diagnostic imaging findings.

Authors:  A Barile; F Bruno; S Mariani; F Arrigoni; A Reginelli; M De Filippo; M Zappia; A Splendiani; E Di Cesare; C Masciocchi
Journal:  Musculoskelet Surg       Date:  2017-02-13

9.  The validity and reliability of ultrasound on identifying supraspinatus tears during passive external rotation from 0° to 30°: a pilot project.

Authors:  June S Kennedy; Heather S Myers; Scott D Gibson; Matthew G Kanaan; Robert J Butler
Journal:  Shoulder Elbow       Date:  2016-07-20

10.  Massive rotator cuff tears: functional outcome after debridement or arthroscopic partial repair.

Authors:  Alexander Berth; Wolfram Neumann; Friedemann Awiszus; Géza Pap
Journal:  J Orthop Traumatol       Date:  2010-03-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.